CALCulate<1...2>:MARKer<1...6>:FUNCtion:DEModulation:HOLD
<HoldTime>
This command defines the hold time at the marker position for the demodulation with
span > 0.
The numeric suffix at CALCulate is irrelevant for this command. The numeric suffix at
MARKer selects the marker.
Parameters:
<HoldTime>
Range:
100 ms to 500 s
*RST:
0.5 (DEModulation is set to OFF)
Default unit: s
Example:
CALC:MARK:FUNC:DEM:HOLD 3s
Sets a hold time of 3 seconds.
CALCulate<1...2>:MARKer<1...6>:FUNCtion:DEModulation:SELect
<DemodType>
This command selects the type of demodulation type for the audio demodulator.
The numeric suffix at CALCulate is irrelevant for this command. The numeric suffix at
MARKer selects the marker.
Parameters:
<DemodType>
AM | FM
*RST:
AM
Example:
CALC:MARK:FUNC:DEM:SEL FM
Selects FM demodulation.
CALCulate<1...2>:MARKer<1...6>:FUNCtion:FIXed
This command synchronizes the bargraph frequency to one of the marker frequencies
in the frequency scan.
At the same, the command switches to the fixed frequency measurement.
The numeric suffix at CALCulate is irrelevant for this command. The numeric suffix at
MARKer selects the marker.
Suffix:
<1...2>
.
1...2
<1...6>
1...6
Usage:
Event
13.6.6.7
Using Limit Lines
The following commands define limit lines and perform the corresponding limit checks.