![Rohde & Schwarz 1321.0615.02 User Manual Download Page 137](http://html1.mh-extra.com/html/rohde-and-schwarz/1321-0615-02/1321-0615-02_user-manual_1477771137.webp)
Spectrum Analyzer Mode
R&S
®
Spectrum Rider FPH
130
User Manual 1321.1011.02 ─ 11
Figure 6-2: Screen layout for the occupied bandwidth
1 = Occupied bandwidth measurement mode
2 = Occupied bandwidth numerical
3 = Measurement standard
4 = Channel bandwidth
5 = Power percentage
6 = Occupied bandwidth graphical (blue lines)
7 =
8 =
9 = Occupied bandwidth measurement softkey menu
6.1.3.1
Selecting a Standard
If you need to perform measurements that are conformed to a telecommunications
standard, you can activate one of the predefined standards that are already stored in
the R&S Spectrum Rider memory. However, you can also use the R&S InstrumentView
to create new configurations to perform measurements on other standards as well. For
more information on creating new configurations, see "Using Standards "in the R&S
InstrumentView.
1. Press [MEAS] key.
2. Select "Standard" softkey.
The R&S Spectrum Rider opens the "File Manager" dialog to select the standard.
3. Select one of the available standards.
4. Confirm the selection with the "Load" softkey.
The R&S Spectrum Rider loads the configuration of the selected standard. It auto-
matically sets the optimal span, resolution bandwidth, video bandwidth, sweep time
and detector for the standard.
Performing Spectrum Measurements
www.allice.de
Allice Messtechnik GmbH