If you do not use a suffix at MARKer, marker 1 is selected. If one or more delta mark-
ers (2 to 6) are already active, the command turns these delta markers into normal
markers.
The numeric suffix at CALCulate is irrelevant for this command. The numeric suffix at
MARKer selects the marker.
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
CALC:MARK3 ON
Turns on marker 3.
CALCulate<1...2>:MARKer<1...6>:AOFF
This command turns off all active markers, delta markers and active marker measure-
ment functions.
This command is an event and therefore has no query and no *RST value.
The numeric suffix at CALCulate is irrelevant for this command. The numeric suffix at
MARKer selects the marker.
Example:
CALC:MARK:AOFF
Switches off all markers.
Usage:
Event
CALCulate<1...2>:MARKer<1...6>:MAXimum[:PEAK]
This command positions a marker on the current trace maximum.
If necessary, the corresponding marker is activated first.
This command is an event and therefore has no *RST value and no query.
The numeric suffix at CALCulate is irrelevant for this command. The numeric suffix at
MARKer selects the marker.
Example:
CALC:MARK2:MAX
Moves marker 2 to the maximum peak.
Usage:
Event
CALCulate<1...2>:MARKer<1...6>:MAXimum:NEXT
This command positions a marker on the next smaller trace maximum.
If necessary, the corresponding marker is activated first.
This command is an event and therefore has no *RST value and no query.
The numeric suffix at CALCulate is irrelevant for this command. The numeric suffix at
MARKer selects the marker.