Remote Commands
R&S
®
Spectrum Rider FPH
464
User Manual 1321.1011.02 ─ 11
Parameters:
<DirectoryName>
String containing the path of the directory to delete.
Example:
MMEM:RDIR '\Public\Screen Shots\
Deletes the directory 'Screen Shots'.
Usage:
Setting only
MMEMory:STORe:STATe
<1>, <TargetFile>
This command stores the current device settings in a *set file.
This command is an event and therefore has no *RST value and no query.
Parameters:
<1>
<TargetFile>
String containing the destinated path and filename of the dataset
to store.
Example:
MMEM:STOR:STAT 1,'DATASET001.SET'
Saves the current device settings in the file DATASET001.SET.
Usage:
Setting only
MMEMory:STORe:CSV:STATe
<1>, <TargetFile>
This command exports dataset to CSV format. The CSV file is saved in the same
folder as the dataset file.
This works for all datasets except spectrogram and spectrogram playback.
Parameters:
<1>
<TargetFile>
String containing the destinated path and filename of the file to
export.
Example:
MMEM:STOR:CSV:STAT 1, '\Public\Datasets\Dataset0001.set'
Export the file Dataset0001.set to Dataset0001.csv
Usage:
Setting only
SYSTem:SET:LOCK
<arg0>
This command adds write-protection to a dataset.
Parameters:
<arg0>
String containing the path and name of the dataset.
Example:
SYST:SET:LOCK 'Dataset001.set'
Protects the file Dataset001.set from overwriting.