[SENSe:]FREQuency:CENTer
<CenterFrequency>
This command defines the center frequency of the R&S Spectrum Rider.
In spectrum analyzer mode, the command also defines the measuring frequency for
time domain measurements (span
=
0).
Parameters:
<CenterFrequency> Range:
Depends on the operating mode and is specified in
the data sheet.
*RST:
fmax /2 with fmax = maximum frequency
Default unit: MHz
Example:
FREQ:CENT 100MHz
Defines a center frequency of 100 MHz.
[SENSe:]FREQuency:CENTer:STEP
<Stepsize>
This command defines the center frequency step size.
Parameters:
<Stepsize>
Range:
1 Hz to fmax
*RST:
- (AUTO 0.1*SPAN is switched on)
Default unit: MHz
Example:
FREQ:CENT:STEP 120MHz
Defines a CF step size of 120 MHz.
[SENSe:]FREQuency:OFFSet
<FreqOffset>
This command defines a frequency offset.
Parameters:
<FreqOffset>
Range:
-100 GHz to 100 GHz
*RST:
0 Hz
Default unit: GHz
Example:
FREQ:OFFS 1GHZ
Defines a frequency offset of 1 GHz.