![Rohde & Schwarz 1321.0615.02 User Manual Download Page 415](http://html1.mh-extra.com/html/rohde-and-schwarz/1321-0615-02/1321-0615-02_user-manual_1477771415.webp)
Remote Commands
R&S
®
Spectrum Rider FPH
408
User Manual 1321.1011.02 ─ 11
13.6.4.4
Configuring the Trigger
The following chapter describes command necessary to configure the trigger signal for
the digital modulation parameters.
List of commands
.......................................................................................... 408
TRIGger[:SEQuence]:LEVel:IQPower
...............................................................................408
........................................................................................408
TRIGger[:SEQuence]:SLOPe
<TriggerSlope>
This command selects the slope of the trigger signal.
The trigger slope applies to all trigger sources.
Parameters:
<TriggerSlope>
POSitive | NEGative
*RST:
POSitive
Example:
TRIG:SLOP NEG
TRIGger[:SEQuence]:LEVel:IQPower
<IQPowerLevel>
This command defines the trigger level of the I/Q power trigger.
Prerequisites for this command: Select I/Q power trigger
Parameters:
<IQPowerLevel>
*RST:
-20
Default unit: dBm
Example:
TRIG:SOUR IQP
TRIG:LEV:IQP -10
Configure I/Q power trigger.
TRIGger[:SEQuence]:SOURce
<TriggerSource>
This command selects the trigger source.
Parameters:
<TriggerSource>
IMMediate | EXTernal | VIDeo | IQPower | GATed
IMMediate
Selects Free Run measurements.
EXTernal
Selects an external trigger.
VIDeo
Selects the video trigger.
IQPower
Selects an IQ Power trigger.
Remote Control - Commands
www.allice.de
Allice Messtechnik GmbH