![background image](http://html1.mh-extra.com/html/omron/cj1w-nc271-12-2009/cj1w-nc271-12-2009_operation-manual_742348247.webp)
219
Transferring Data
Section 5-1
Transferring Servo Drive
Parameters
Servo Parameters are stored in internal memory of the Servo Drive connected
to the PCU and then saved in the Servo Drive's non-volatile memory. These
parameters are read/written or saved to the non-volatile memory from the
CPU Unit using the WRITE SERVO PARAMETER, READ SERVO PARAME-
TER, and SAVE SERVO PARAMETER Bits allocated in the Axis Operating
Memory Areas.
Servo Parameters for a single axis are written and read by parameter by spec-
ifying the parameter number. Parameters for different axes can be transferred
at the same time.
Servo Parameters are saved by executing WRITE DATA to write them to the
Servo Drive's non-volatile memory. Therefore, SAVE SERVO PARAMETER
must be executed for each parameter separately from writing them to the
Servo Drive's memory (WRITE SERVO PARAMETER).
Two types of Servo Parameters are transferred to the Servo Drive: online
parameters with set values that are enabled immediately after they are writ-
ten, and offline parameters, which are not enabled just by writing them. To
enable set values for offline parameters in Servo Drive operations, save the
parameters to the non-volatile memory, and then cycle the Servo Drive power.
Alternatively, execute WRITE SERVO PARAMETER/SAVE SERVO PARAME-
TER and then execute the Servo Drive's DEVICE SETUP.
When DEVICE SETUP is executed, the Servo Drive enables all the Servo
Parameters that are currently being transferred, and initializes the present
position and output signal status to set the Servo Drive.
MOV
MOV
MOV
MOV
Ladder program
WRITE DATA
READ DATA
SAVE DATA
CPU Unit
PCU
Writing data
Reading data
Saving data
Internal memory
Powerup
or restart
Flash memory
Summary of Contents for CJ1W-NC271 - 12-2009
Page 2: ......
Page 4: ...iv ...
Page 6: ...vi ...
Page 22: ...xxii ...
Page 58: ...30 Starting Operation Section 2 2 ...
Page 244: ...216 Axis Operating Input Memory Areas Section 4 8 ...
Page 264: ...236 Transferring Servo Parameters Section 5 3 ...
Page 396: ...368 Linear Interpolation Section 9 7 ...
Page 648: ...620 List of Error Codes Appendix D ...
Page 674: ...646 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Page 684: ...656 Index ...
Page 686: ...658 Revision History ...