320
Origin Return
Section 8-4
The command unit default setting is pulses.
G5-series Acceleration/Deceleration Constants
G-series Acceleration/Deceleration Constants
W-series and SMARTSTEP Junior Acceleration/Deceleration Constants
Type
Parame-
ter No.
Parameter name
Unit
Setting
range
Parame-
ter size
Default
setting
Accel-
eration/
decel-
eration
con-
stants
Pn811
Linear acceleration constant
10,000
command
units/s
2
−
32768
to 32767
2
100
Pn814
Linear deceleration constant
10,000
command
units/s
2
−
32768
to 32767
2
100
Accel-
eration/
decel-
eration
filters
Pn818
Position command FIR filter
time constant
0.1 ms
0 to
10000
2
0
Type
Parame-
ter No.
Parameter name
Unit
Setting
range
Parame-
ter size
Default
setting
Accel-
eration/
decel-
eration
con-
stants
Pn107
Linear acceleration constant
10,000
command
units/s
2
−
32768
to 32767
2
100
Pn10A
Linear deceleration constant
10,000
command
units/s
2
−
32768
to 32767
2
100
Accel-
eration/
decel-
eration
filters
Pn10E
Moving average time
0.1 ms
0 to 5100 2
0
Type
Parame-
ter No.
Parameter name
Unit
Setting
range
Parame-
ter size
Default
setting
W Series
SMART-
STEP
Junior
Accel-
eration/
decel-
eration
con-
stants
Pn80A
First-step linear acceleration
constant
10,000
command
units/s
2
1 to
65535
2
100
Sup-
ported
Not sup-
ported
Pn80B
Second-step linear accelera-
tion constant
10,000
command
units/s
2
1 to
65535
2
100
Sup-
ported
Sup-
ported
Pn80C
Acceleration constant switch-
ing speed
100 com-
mand
units/s
0 to
65535
2
0
Sup-
ported
Not sup-
ported
Pn80D
First-step linear deceleration
constant
10,000
command
units/s
2
1 to
65535
2
100
Sup-
ported
Not sup-
ported
Pn80E
Second-step linear decelera-
tion constant
10,000
command
units/s
2
1 to
65535
2
100
Sup-
ported
Sup-
ported
Pn80F
Deceleration constant switch-
ing speed
100 com-
mand
units/s
0 to
65535
2
0
Sup-
ported
Not sup-
ported
Summary of Contents for CJ1W-NC271 - 12-2009
Page 2: ......
Page 4: ...iv ...
Page 6: ...vi ...
Page 22: ...xxii ...
Page 58: ...30 Starting Operation Section 2 2 ...
Page 244: ...216 Axis Operating Input Memory Areas Section 4 8 ...
Page 264: ...236 Transferring Servo Parameters Section 5 3 ...
Page 396: ...368 Linear Interpolation Section 9 7 ...
Page 648: ...620 List of Error Codes Appendix D ...
Page 674: ...646 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Page 684: ...656 Index ...
Page 686: ...658 Revision History ...