537
List of Parameters
Appendix B
Pn003
Torque
Limit Selec-
tion
2
Note
PCL ON: When either Forward Torque Limit (CN1 PCL:
pin 7) or MECHATROLINKII Communications
Option Field (P-CL) is ON.
PCL OFF: When both Forward Torque Limit (CN1 PCL:
pin 7) and MECHATROLINK-II Communica-
tions Option Field (P-CL) are OFF.
1
---
1 to 5
Online
Settings
can be
changed
when the
axes are
stopped
(Busy
Flag for
each axis
= 0).
• Torque Feed-forward Function Selection
1 to 3
Enabled only during speed control. Disabled if not
using speed control.
4 to 5
Always disabled
Pn004
Drive Pro-
hibit Input
Selection
2
Sets the function for the Forward and Reverse Drive Prohibit
Inputs (CN1 POT: pin 19, NOT: pin 20)
0
---
0 to 2
Offline
0
Decelerates and stops according to the sequence set
in the Stop Selection for Drive Prohibition Input (Pn066)
when both POT and NOT inputs are enabled.
When both POT and NOT inputs are OPEN, the Drive
Prohibit Input Error (alarm code 38) will occur.
1
Both POT and NOT inputs disabled.
2
When either POT or NOT input becomes OPEN, the
Drive Prohibit Input Error (alarm code 38) will occur.
Pn005
Communi-
cations
Control
2
Controls errors and warnings for MECHATROLINK-II communica-
tions.
Note
Use with thi]s parameter set to 0. Program to stop immedi-
ately if using a value other than 0.
Set the Consecutive Communications Error Detection Count in
COM_ERR (bit 8 to 11). The communications error (alarm code
83) will occur when a communications error, which is assessed at
every MECHATROLINK-II communications cycle, occurs consecu-
tively for the number of the Consecutive Communications Error
Detection Count. The error and warning can be masked for debug
purposes.
• [bits 8-11] COM_ERR (Consecutive Communications
Error Detection Count)
Setting range: 0 to 15.
Consecutive Communications Error Detection
Count = C 2
Note
These bits are debug functions. Set to enable (0) when
not debugging.
• [bits 0-3] MECHATROLINK-II Communications Alarms Mask
(MSK COM ALM)
[bit0]0: Communications error (alarm code 83) enabled
1: Communications error (alarm code 83) disabled
[bit1]0: Watchdog data error (alarm code 86) enabled
1: Watchdog data error (alarm code 86) disabled
• [bits 4-7] MECHATROLINK-II Communications Warnings Mask
(MSK COM WARNG)
[bit4]0: Data setting warning (warning code 94h) enabled
1: Data setting warning (warning code 94h) disabled
[bit5]0: Command warning (warning code 95h) enabled
1: Command warning (warning code 95h) disabled
[bit6]0: ML-II communications warning
(warning code 96h) enabled
1: ML-II communications warning
(warning code 96h) disabled
0
---
0 to 3955
Offline
Always
set to 0.
Pn006
Power ON
Address
Display
Duration
Setting
2
Sets the duration to display the node address when the control
power is turned ON.
Note
The node address display has priority even if there are
alarms or warnings at power ON.
30
ms
0 to 1000
Offline
0 to 6
600 ms
7 to
1000
set value
×
100 ms
Param-
eter
No.
Parameter
name
Param-
eter
size
Setting
Explanation
Default
setting
Unit
Setting
range
Enable
setting
Details
bits 15-12
bits 11-8
bits 7-4
bits 3-0
---
COM_ERR
MSK COM
WARNG
MSK COM
ALM
Summary of Contents for CJ1W-NC271 - 12-2009
Page 2: ......
Page 4: ...iv ...
Page 6: ...vi ...
Page 22: ...xxii ...
Page 58: ...30 Starting Operation Section 2 2 ...
Page 244: ...216 Axis Operating Input Memory Areas Section 4 8 ...
Page 264: ...236 Transferring Servo Parameters Section 5 3 ...
Page 396: ...368 Linear Interpolation Section 9 7 ...
Page 648: ...620 List of Error Codes Appendix D ...
Page 674: ...646 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Page 684: ...656 Index ...
Page 686: ...658 Revision History ...