323
Origin Return
Section 8-4
Note
Do not set both the exponential curve designation and S-curve designation to
1 (enabled) in the acceleration/deceleration curve designation. Enabling both
settings may cause a malfunction.
Axis Operating Input Memory Areas (Monitor)
b = Beginning word of Axis Operating Input Areas specified in Common
Para (Axis No.
−
1)
×
25
Timing Chart
The following timing chart is for when ORIGIN RETURN is executed.
Name
Word
Bits
Contents
PCU Positioning Com-
pleted Flag
b
05
0
→
1: Positioning completed.
No Origin Flag
06
0: Origin established.
1: No origin established.
Origin Stop Flag
07
0: Outside origin range.
1: Within origin range.
Error Flag
12
0: No axis error.
1: Axis error.
Busy Flag
13
1: Axis busy (axis operation executing).
Feedback present posi-
tion
b+6
b+7
---
Present position:
Feedback present position (rightmost
word)
Feedback present position (leftmost
word)
Command present posi-
tion
b+8
b+9
---
Present position:
Command position (rightmost word)
Command position (leftmost word)
3E8 hex (1000)
Speed command value
(words a+4, a+5)
ORIGIN RETURN
(word a, bit 07)
Speed
Origin Stop Flag
(word b, bit 07)
PCU Positioning Complet-
ed Flag (word b, bit 05)
Target speed: 1,000
(command units/s)
Solid line: Command speed
Broken line: Feedback speed
Time
a = Beginning word of Axis Operating Output Areas specified in Common Para (Axis No.
−
1)
×
25
b = Beginning word of Axis Operating Input Areas specified in Common Para (Axis No.
−
1)
×
25
The PCU Positioning Completed Flag is turned OFF
when a movement command is executed.
The PCU Positioning Completed Flag is turned ON
when the number of the Servo Drive's deviation counter
residual pulses is less than the value set for the
positioning completion range. Depending on the number
of deviation counter residual pulses when pulse output
has been completed, a delay may occur in the time
between when the pulse output from the Position
Control Unit is completed until positioning has been
completed.
Summary of Contents for CJ1W-NC271 - 12-2009
Page 2: ......
Page 4: ...iv ...
Page 6: ...vi ...
Page 22: ...xxii ...
Page 58: ...30 Starting Operation Section 2 2 ...
Page 244: ...216 Axis Operating Input Memory Areas Section 4 8 ...
Page 264: ...236 Transferring Servo Parameters Section 5 3 ...
Page 396: ...368 Linear Interpolation Section 9 7 ...
Page 648: ...620 List of Error Codes Appendix D ...
Page 674: ...646 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Page 684: ...656 Index ...
Page 686: ...658 Revision History ...