132
Servo Parameter Area
Section 4-5
4-5-3
W-series Servo Drives (R88D-WT
@
with FNY-NS115)
The Servo Parameters listed here can be used when the Position Control Unit
is used with an OMRON W-series Servo Drive (R88D-WT
@
) with a MECHA-
TROLINK-II I/F Unit (FNY-NS115).
For further details on each of the parameters, refer to the user’s manuals for
W-series Servo Drives and MECHATROLINK-II I/F Unit (FNY-NS115).
The default settings for parameters Pn000 to Pn601 in the parameter tables
for the R88D-WT
@
W-series Servo Drive used with the FNY-NS115 are auto-
matically set to the default parameter settings for when the FNY-NS115
MECHATROLINK-II I/F Unit is mounted to a W-series Servo Drive. Parame-
ters from Pn800 onwards are enabled when the FNY-NS115 is mounted. The
parameter names and default settings for these parameters follow those spec-
ified by the FNY-NS115.
The timing for Servo Parameters to be enabled are classified into the following
two types.
Online (online parameter): Changed settings are enabled immediately after
Servo Parameters have been written.
Offline (offline parameters): Changed settings are enabled when the Servo
Drive power is cycled or DEVICE SETUP is exe-
cuted.
The
Details
column indicates whether the following conditions apply to the
corresponding parameter.
• Online parameters that can be changed when the axis is stopped (Busy
Flag = 0) only.
• Parameters that are automatically set when a FNY-NS115 MECHA-
TROLINK-II I/F Unit is installed and Parameters that are used with fixed
set values are indicated in the
Details
column as "fixed" with the set value.
• Parameters with standard set values when using MECHATROLINK are
indicated in the
Details
column as "standard" with the set value. The stan-
dard settings are basic settings required when using the Position Control
Unit. This manual describes operations assuming standard settings are
being used.
For details on fixed and standard settings, refer to
6-4 Standard Settings for
Servo Drives Using MECHATROLINK
.
Note
Make sure that the equipment will not be adversely affected before changing
the Servo Parameters (WRITE SERVO PARAMETER, SAVE SERVO
PARAMETER). Refer to the Servo Drive's user’s manual and always check
the effect of changing the settings before changing the Servo Parameters.
Summary of Contents for CJ1W-NC271 - 12-2009
Page 2: ......
Page 4: ...iv ...
Page 6: ...vi ...
Page 22: ...xxii ...
Page 58: ...30 Starting Operation Section 2 2 ...
Page 244: ...216 Axis Operating Input Memory Areas Section 4 8 ...
Page 264: ...236 Transferring Servo Parameters Section 5 3 ...
Page 396: ...368 Linear Interpolation Section 9 7 ...
Page 648: ...620 List of Error Codes Appendix D ...
Page 674: ...646 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Page 684: ...656 Index ...
Page 686: ...658 Revision History ...