139
Servo Parameter Area
Section 4-5
I/O and Status Parameters
Pn403
Reverse
torque limit
2
Reverse rotation output torque limit (rated torque
ratio).
350
%
0 to 800 Online
---
Pn404
Forward
rotation
external
current
limit
2
Output torque limit during input of forward rotation cur-
rent limit (rated torque ratio).
100
%
0 to 800 Online
---
Pn405
Reverse
rotation
external
current
limit
2
Output torque limit during input of reverse rotation cur-
rent limit (rated torque ratio).
100
%
0 to 800 Online
---
Pn406
Emer-
gency stop
torque
2
Deceleration torque when an error occurs (rated
torque ratio).
350
%
0 to 800 Online
---
Pn407
Speed
limit
2
Sets the speed limit in torque control mode.
3000
r/min
0 to
10000
Online
---
Pn408
Torque
command
setting
2
0
Selects notch
filter 1 function
0
Notch filter 1 not
used.
0
---
---
Online
---
1
Notch filter 1 used
for torque com-
mands.
1
Not used.
0
(Do not change the
setting.)
0
---
---
---
---
2
Selects notch
filter 2 function
0
Notch filter 2 not
used.
0
---
---
Online
---
1
Notch filter 2 used
for torque com-
mands.
3
Not used.
0
(Do not change the
setting.)
0
---
---
---
---
Pn409
Notch fil-
ter 1 fre-
quency
2
Sets notch filter 1 frequency for torque command.
2000
Hz
50 to
2000
Online
---
Pn40A
Notch fil-
ter 1 Q
value
2
Sets Q value of notch filter 1.
70
×
0.01
50 to
400
Online
---
Pn40B
Notch fil-
ter 2 fre-
quency
2
Sets notch filter 2 frequency for torque command.
2000
Hz
50 to
2000
Online
---
Pn40C
Notch fil-
ter 2 Q
value
2
Sets Q value of notch filter 2.
70
×
0.01
50 to
400
Online
---
Param-
eter No.
Parame-
ter name
Param-
eter
size
Contents
Default
setting
Unit
Setting
range
Enable
setting
Details
Digit
No.
Name
Set-
ting
Explanation
Pn500
Position-
ing com-
pletion
range 1
2
Sets the width of the positioning completed range.
3
Com-
mand
unit
0 to 250 Online
---
Pn501
Not used.
---
(Do not change the setting.)
10
---
---
---
---
Pn502
Rotation
speed for
motor rota-
tion detec-
tion
2
Sets the number of rotations for detecting the Zero
Speed Flag.
20
r/min
1 to
10000
Online
---
Pn503
Speed
conformity
signal out-
put width
2
Sets the allowable fluctuation range (rotation speed)
for the Speed Conformity Flag.
10
r/min
0 to 100 Online
---
Pn504
Position-
ing com-
pletion
range 2
2
Sets the proximity range for the Positioning Proximity
Flag.
3
Com-
mand
unit
1 to 250 Online
---
Param-
eter No.
Parame-
ter name
Param-
eter
size
Contents
Default
setting
Unit
Setting
range
Enable
setting
Details
Digit
No.
Name
Set-
ting
Explanation
Summary of Contents for CJ1W-NC271 - 12-2009
Page 2: ......
Page 4: ...iv ...
Page 6: ...vi ...
Page 22: ...xxii ...
Page 58: ...30 Starting Operation Section 2 2 ...
Page 244: ...216 Axis Operating Input Memory Areas Section 4 8 ...
Page 264: ...236 Transferring Servo Parameters Section 5 3 ...
Page 396: ...368 Linear Interpolation Section 9 7 ...
Page 648: ...620 List of Error Codes Appendix D ...
Page 674: ...646 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Page 684: ...656 Index ...
Page 686: ...658 Revision History ...