151
Servo Parameter Area
Section 4-5
4-5-4
W-series Servo Drive (R88D-WN
@
-ML2 with Built-in
MECHATROLINK-II Communications)
The Servo Parameters listed here can be used when the Position Control Unit
is used with a W-series Servo Drive with Built-in MECHATROLINK-II Commu-
nications (R88D-WN
@
-ML2).
For further details on each of the parameters, refer to the user’s manual for W-
series Servo Drives.
The timing for Servo Parameters to be enabled are classified into the following
two types.
Online (online parameter): Changed settings are enabled immediately after
Servo Parameters have been written.
Offline (offline parameters): Changed settings are enabled when the Servo
Drive power is cycled or DEVICE SETUP is exe-
cuted.
The
Details
column indicates whether the following conditions apply to the
corresponding parameter.
• Online parameters that can be changed when the axis is stopped (Busy
Flag = 0) only.
• Parameters with standard set values when using MECHATROLINK are
indicated in the
Details
column as "standard" with the set value. The stan-
dard settings are basic settings required when using the Position Control
Unit. This manual describes operations assuming standard settings are
being used.
For details on fixed and standard settings, refer to
6-4 Standard Settings for
Servo Drives Using MECHATROLINK
.
Note
Make sure that the equipment will not be adversely affected before changing
the Servo Parameters (WRITE SERVO PARAMETER, SAVE SERVO
PARAMETER). Refer to the Servo Drive's user’s manual and always check
the effect of changing the settings before changing the Servo Parameters.
Function Selection Parameters
Param-
eter No.
Parame-
ter name
Param-
eter
size
Contents
Default
setting
Unit
Setting
range
Enable
setting
Details
Digit
No.
Name
Set-
ting
Explanation
Pn000
Function
selection
basic
switches
2
0
Reverse rota-
tion
0
CCW direction is
taken for positive
command
0
---
---
Offline
---
1
CW direction is
taken for positive
command
2 to 3
Not used.
1
Not used.
0
(Do not change the
setting.)
0
---
---
---
---
2
Unit No. setting 0 to F
Servo Drive com-
munications unit
number setting
(necessary for mul-
tiple Servo Drive
connections when
using personal
computer monitor-
ing software)
0
---
---
Offline
---
3
Not used.
0
(Do not change the
setting.)
0
---
---
---
---
Summary of Contents for CJ1W-NC271 - 12-2009
Page 2: ......
Page 4: ...iv ...
Page 6: ...vi ...
Page 22: ...xxii ...
Page 58: ...30 Starting Operation Section 2 2 ...
Page 244: ...216 Axis Operating Input Memory Areas Section 4 8 ...
Page 264: ...236 Transferring Servo Parameters Section 5 3 ...
Page 396: ...368 Linear Interpolation Section 9 7 ...
Page 648: ...620 List of Error Codes Appendix D ...
Page 674: ...646 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Page 684: ...656 Index ...
Page 686: ...658 Revision History ...