![background image](http://html1.mh-extra.com/html/omron/cj1w-nc271-12-2009/cj1w-nc271-12-2009_operation-manual_742348358.webp)
330
Absolute Encoder Origin
Section 8-6
Parameters for Using G-series Absolute Encoders
Parameters for Using W-series Absolute Encoders
When using a Servomotor with an absolute encoder, select whether the abso-
lute encoder will be used as an absolute encoder or as an incremental
encoder. Set this parameter to 0 if using the absolute encoder as an absolute
encoder.
When using W-series Servo Drives, the parameter size is the value to be
specified when transferring the Servo Parameter including Pn002.
G-series Origin Position Offset Parameters
G5-series/W-series Origin Position Offset Parameters
This parameter sets the offset for the mechanical origin from the absolute
encoder's absolute value data. The present position will be the absolute value
data that was read added to the value in this parameter, and that position is
set as the origin.
Note
When using the zero point position offset setting function with Position Control
Units with unit version 2.0 or later, Pn808 is automatically overwritten when an
origin search is performed with an absolute encoder. (Refer to
8-6-5 Absolute
Encoder's Origin (Zero Point) Position Offset Setting
) To achieve this, the
Position Control Unit reads and writes Servo Parameter for Pn808 when the
origin search operation is started and when it is completed.
Axis Operating Input Memory Areas (Monitor)
Type
Parameter
No.
Parameter name
Unit
Setting
range
Parameter
size
Default
setting
---
Pn00B
Operation switch when using absolute
encoder
---
0 to 2
2
0
Type
Parameter
No.
Parameter name
Unit
Setting
range
Parameter
size
Default
setting
---
Pn002.2
Function selection application switch 2
(operation switch when using absolute
encoder)
---
0, 1
2
0
Type
Parameter
No.
Parameter name
Unit
Setting range
Parameter
size
Default
setting
---
Pn200
Absolute origin offset
Command unit
−
1,073,741,823
to
1,073,741,823
4
0
Type
Parameter
No.
Parameter name
Unit
Setting range
Parameter
size
Default
setting
---
Pn808
Absolute encoder zero point
position offset
Command unit
−
1,073,741,823
to
1,073,741,823
4
0
Name
Word
Bits
Contents
No Origin Flag
b
06
0: Origin established.
1: No origin established.
Origin Stop Flag
07
0: Outside origin range.
1: Within origin range.
Error Flag
12
0: No axis error.
1: Axis error.
Busy Flag
13
1: Axis busy (axis operation executing).
Summary of Contents for CJ1W-NC271 - 12-2009
Page 2: ......
Page 4: ...iv ...
Page 6: ...vi ...
Page 22: ...xxii ...
Page 58: ...30 Starting Operation Section 2 2 ...
Page 244: ...216 Axis Operating Input Memory Areas Section 4 8 ...
Page 264: ...236 Transferring Servo Parameters Section 5 3 ...
Page 396: ...368 Linear Interpolation Section 9 7 ...
Page 648: ...620 List of Error Codes Appendix D ...
Page 674: ...646 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Page 684: ...656 Index ...
Page 686: ...658 Revision History ...