215
Axis Operating Input Memory Areas
Section 4-8
Example: If a W-series Servo Drive equipped with a FNY-NS115
MECHATROLINK-II I/F Unit is connected, the minimum resolution of
the monitor values for feedback speed and command speed during po-
sition/torque control is 1,000 command units/s.
Depending on the length of the PLC cycle and MECHATROLINK commu-
nications cycle short-term changes of the Servo Drive status may not be
monitored successfully.
(2) If MECHATROLINK communications are stopped (connection released)
during speed or torque control and MECHATROLINK communications
are restarted to execute SERVO LOCK (Servo ON), the power to the Ser-
vomotor will be recovered with the previous control mode maintained. At
this point, the PCU cannot obtain correct monitor values for speed or
torque monitor in its expanded monitoring.
To stop MECHATROLINK communications during SPEED CONTROL or
TORQUE CONTROL execution, either execute DECELERATION STOP
or EMERGENCY STOP, or execute SERVO UNLOCK, change to the po-
sition control mode, and then release the connection.
Summary of Contents for CJ1W-NC271 - 12-2009
Page 2: ......
Page 4: ...iv ...
Page 6: ...vi ...
Page 22: ...xxii ...
Page 58: ...30 Starting Operation Section 2 2 ...
Page 244: ...216 Axis Operating Input Memory Areas Section 4 8 ...
Page 264: ...236 Transferring Servo Parameters Section 5 3 ...
Page 396: ...368 Linear Interpolation Section 9 7 ...
Page 648: ...620 List of Error Codes Appendix D ...
Page 674: ...646 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Page 684: ...656 Index ...
Page 686: ...658 Revision History ...