diSP
EWS-102 CONTROL UNIT
SYSTEM SETUP
Firmware 2.5 Rev 1 subje
a era i
CAP
hyst
Select the first menu item.
CAP indicates the elevator maximum capacity. To view the current value press
AL 1 is the load value to trigger Alarm Relay 1. To view the current value press
AL 2 is the load value to trigger Alarm Relay 2. To view the current value press
Save and return to normal operation by pressing
twice
An internal sounder beeps when an overload alarm is triggered or when the keypad is pressed.
To change the setting, press
and use
To toggle beteween On and OFF.
To begin the system
setup, press the
and
buttons together.
Enter the system setup menu.
www.garan.co.uk
Op on for turning the display on or off when the li is moving, the door close signal
ac vates. To change the setting, press
and use
To toggle between On and OFF.
The filter value determines the update rate and damping factor. The available settings are:
0 = 0.4sec, 1 = 0.8sec, 2 = 1.2sec, 3 = 1.6sec.
Defines the time from the control signal input is activated and the car load is stored.
Default =2, the available settings are: 0 = 0sec, 1 = 0.5sec, .....7 = 3.5sec.
Defines the value by which the load in the lift has to drop to reset the instrument,
once the alarm has been triggered.
AL 3 is similar to Alarms 1 & 2 but allows negative values to be entered. When editing the
most significant digit, instead of rolling over from 9 to 0 it included the minus sign option.
dLy
FIL
bEEP
The system setup menu allows you to set and adjust various
system parameters.
Naviga on
Use the
bu on to step through the menu items.
Press
to view the menu item
When a value is displayed, use
to select the digit to
edit (selected digit flashes) and use
to step through the
values for that digit.
Press
to save a change. The system will revert to the
opera onal display a er approx. 10 seconds. Alterna vely,
return to the opera onal display by pressing
twice
Edi ng Values
Un l a sensor is connected, the EWS will display
Err6
preven ng access to the system setup and calibra on menus
To calibrate the EWS 102, a link must be fi ed to the control
signal input terminals
For further informa on refer to EWS 102 User Manual
Notes
5rES
AL 1
AL 1
AL 2
AL 3
Op on to turn the systems reset func on on or off. Leave OFF during system set up and zero and
load calibra on. Select ON a er calibra on and before entering the li into service.
To change the setting, press
and use
To toggle beteween On and OFF.