Managed Switch CLI Manual, Release 8.0
Stacking Commands
2-8
v1.0, July 2009
show switch
This command displays information about all units in the stack or a single unit when you specify
the unit value.
When you do not specify a value for
<unit>
, the following information appears:
When you specify a value for
<unit>
, the following information appears:
Format
show switch
[<unit>]
Mode
Privileged EXEC
Term
Definition
Switch
The unit identifier assigned to the switch.
Term
Definition
Management
Status
Indicates whether the switch is the Primary Management Unit, a stack member, or the
status is unassigned.
Preconfigured
Model Identifier
The model identifier of a preconfigured switch ready to join the stack. The Model
Identifier is a 32-character field assigned by the device manufacturer to identify the
device.
Plugged-In Model
Identifier
The model identifier of the switch in the stack. Model Identifier is a 32-character field
assigned by the device manufacturer to identify the device.
Switch Status
The switch status. Possible values for this state are: OK, Unsup ported, Code
Mismatch, Config Mismatch, or Not Present.
Code Version
The detected version of code on this switch.
Term
Definition
Management
Status
Indicates whether the switch is the Primary Management Unit, a stack member, or the
status is unassigned.
Hardware
Management
Preference
The hardware management preference of the switch. The hardware management
preference can be disabled or unassigned.
Admin
Management
Preference
The administrative management preference value assigned to the switch. This
preference value indicates how likely the switch is to be chosen as the Primary
Management Unit.
Switch Type
The 32-bit numeric switch type.
Model Identifier
The model identifier for this switch. Model Identifier is a 32-character field assigned by
the device manufacturer to identify the device.
Summary of Contents for FSM726v3 - ProSafe Fast Ethernet L2 Managed Switch
Page 4: ...v1 0 July 2009 iv...