Managed Switch CLI Manual, Release 8.0
Management Commands
7-42
v1.0, July 2009
snmp-server community ipaddr
This command sets a client IP address for an SNMP community. The address is the associated
community SNMP packet sending address and is used along with the client IP mask value to
denote a range of IP addresses from which SNMP clients may use that community to access the
device. A value of 0.0.0.0 allows access from any IP address. Otherwise, this value is ANDed with
the mask to determine the range of allowed client IP addresses. The name is the applicable
community name.
no snmp-server community ipaddr
This command sets a client IP address for an SNMP community to 0.0.0.0. The name is the
applicable community name.
snmp-server community ipmask
This command sets a client IP mask for an SNMP community. The address is the associated
community SNMP packet sending address and is used along with the client IP address value to
denote a range of IP addresses from which SNMP clients may use that community to access the
device. A value of 255.255.255.255 will allow access from only one station, and will use that
machine's IP address for the client IP address. A value of 0.0.0.0 will allow access from any IP
address. The name is the applicable community name.
Default
0.0.0.0
Format
snmp-server community ipaddr
<ipaddr> <name>
Mode
Global Config
Format
no snmp-server community ipaddr
<name>
Mode
Global Config
Default
0.0.0.0
Format
snmp-server community ipmask <ipmask> <name>
Mode
Global Config
Summary of Contents for FSM726v3 - ProSafe Fast Ethernet L2 Managed Switch
Page 4: ...v1 0 July 2009 iv...