background image

 

 

9 P i n   G a n g   R o l l   R o u t e r  

 

 

 

 

 

 

 

U s e r   M a n u a l  

 

 

 

 

Summary of Contents for GangWay32

Page 1: ...9Pin Gang Roll Router User Manual ...

Page 2: ...r Electronics All other brand names are the property of their respective owners Gangway32 User Manual First Edition October 18 2017 Part Number 932154 2017 JLCooper Electronics 142 Arena Street El Segundo CA 90245 USA 310 322 9990 310 335 0110 www jlcooper com ...

Page 3: ...3 Table of Contents Introduction 4 Installation 5 Unpacking 5 Setup 5 Connecting the Gangway32 6 Using the Gangway32 7 Technical Reference 9 Troubleshooting 11 Care and Service 11 ...

Page 4: ...he unit has 54 illuminated pushbutton switches to configure and show the port routing Connections include two 9 pin D Sub connectors for controllers 1 on the rear panel 1 on the front panel and 32 9 pin D Sub connectors for devices such as VTR decks video servers and switchers The unit can be powered from the supplied power adaptor or powered from 9 12 volts DC ...

Page 5: ...er your product at http www jlcooper com This will allow us to notify you of important updates and changes Setup The Gangway32 s compact 1U rack mount design makes it easy to locate wherever you need it The Gangway32 must be setup up in a location that does not experience vibration excessive humidity dust or temperature extremes The Gangway32 can be mounted in any orientation ...

Page 6: ...wing diagram Connect your deck controller into the Controller port on the rear panel Alternately your deck controller can be plugged into the Controller port on the front panel if it is more convenient In this case make sure the front panel Enable button is illuminated Connect your slave devices to the numbered ports on the rear panel You can connect up to 32 slave devices to the Gangway32 ...

Page 7: ...es has been pressed Tally Select The Tally Select switch allows you to route Tally messages device status and responses back to the controller Pressing this button allows you to use the numbered buttons to select the slave device that returns tally messages back to the controller Only one slave device at a time can return tally back to the controller Group Select The Group Select switches allow yo...

Page 8: ...elect is lit The state of the Front Panel Enable LED is not stored The All button is turned off Enable The Enable button selects the front panel controller port If the Enable button is illuminated the Gangway32 uses the front panel controller port If the Enable button is extinguished the Gangway32 uses the rear panel controller port ...

Page 9: ...e Interface outputs The inputs can be used to sense external signals such as tallies and alarms These pins are a CMOS input The input signal must be limited to between 0 and 5 volts referenced to ground This input is pulled up to 5 volts with an internal pullup resistor This makes it compatible with dry relay contacts optoisolators and open collector outputs The outputs can be used to trigger exte...

Page 10: ...ut 23 Input 31 17 Input 8 Input 16 Input 24 Input 32 18 Ground Ground Ground Ground 19 Ground Ground Ground Ground 20 Ground Ground Ground Ground 21 Ground Ground Ground Ground 22 Output 7 Output 15 Output 23 Output 31 23 Output 6 Output 14 Output 22 Output 30 24 Output 4 Output 12 Output 20 Output 28 25 Output 2 Output 10 Output 18 Output 26 GPI Pinout Power The Gangway32 requires a 9 12 volt DC ...

Page 11: ...ent information on drivers applications and troubleshooting Below are listed some possible issues and solutions If all else fails you can contact the JLCooper Service Department at service jlcooper com Care and Service If properly cared for your Gangway32 should provide years of troublefree performance While the Gangway32 is built in a rugged enclosure please avoid dropping the Gangway32 Clean wit...

Page 12: ... approximately 15 business days from receipt of product to shipping Your actual turn around time will include return shipping Actual turn around time will vary depending upon many factors including the repeatability of the customer s reported complaint the availability of parts required for repair the availability of related products needed to evaluate the product if necessary Priority services ar...

Reviews: