Part 5: Review on Replacement of MR-J3-DU_ with MR-J4-DU_
5 - 56
(2) For control circuit power supply
When the wiring for the control circuit power supply (L11/L21) is thinner than that for the main circuit
power supply (L1/L2/L3), install an overcurrent protection device (molded-case circuit breaker or fuse) to
protect the branch circuit.
(a) Converter unit
Converter unit
Molded-case circuit breaker (Note)
Fuse (Class T)
Fuse (Class K5)
Frame, rated current
Voltage AC [V]
Current [A]
Voltage AC [V] Current [A] Voltage AC [V]
MR-CR55K
30 A frame 5 A
240
1
300
1
250
MR-CR55K4
30 A frame 5 A
480
1
600
1
600
Note. When having the converter unit comply with the IEC/EN/UL/CSA standard, refer to "MR-CV_/MR-CR55K_/MR-J4-DU_(-
RJ) instruction manual".
(b) Drive unit
Drive unit
Molded-case circuit breaker (Note)
Fuse (Class T)
Fuse (Class K5)
Frame, rated current
Voltage AC [V]
Current [A]
Voltage AC [V] Current [A] Voltage AC [V]
MR-J4-DU30K_
30 A frame 5 A
240
1
300
1
250
MR-J4-DU37K_
MR-J4-DU30K_4
30 A frame 5 A
480
1
600
1
600
MR-J4-DU37K_4
MR-J4-DU45K_4
MR-J4-DU55K_4
Note. When having the drive unit comply with the IEC/EN/UL/CSA standard, refer to "MR-CV_/MR-CR55K_/MR-J4-DU_(-RJ)
instruction manual".
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...