Part 3: Review on Replacement of MR-J3-_B_ with MR-J4-_B_
3 - 34
MR-J3-_B_
MR-J4-_B_
No.
Name and function
Initial
value
No.
Name and function
Initial
value
PC01 Error excessive alarm level
This parameter cannot be used in the speed control
mode or in the torque control mode.
Set error excessive alarm level with rotation amount of
servo motor.
Note 1. Setting can be changed in [Pr. PC06].
2. For a servo amplifier with software version of B2
or later, reactivating the power supply to enable
the setting value is not necessary. For a servo
amplifier with software version of earlier than B2,
reactivating the power supply is required to
enable the setting value.
Check the software version using Setup software
(SETUP221E).
3
PC01 Error excessive alarm level
Set an error excessive alarm level.
Set this per rev. for rotary servo motors and direct drive
motors. Setting "0" will be 3 rev. Setting over 200 rev will
be clamped with 200 rev.
0
PC02 Electromagnetic
brake sequence output
Used to set the delay time (Tb) between electronic brake
interlock (MBR) and the base drive circuit is shut-off.
0 PC02
Same as MR-J3
0
Electromagnetic brake sequence output
This is used to set the delay time between MBR
(Electromagnetic brake interlock) and the base drive
circuit is shut-off.
PC03 Encoder output pulse selection
Use to select the, encoder output pulse direction and
encoder output pulse setting.
0000h PC03 Same setting as MR-J3
Encoder output pulse selection
This is used to select the encoder pulse direction and
encoder output pulse setting.
0 0 _ x:
Encoder output pulse phase changing
Changes the phases of A, B-phase encoder pulses
output.
Setting
value
Servo motor rotation direction
CCW CW
0
A-phase
B-phase
A-phase
B-phase
1
A-phase
B-phase
A-phase
B-phase
_ _ _ x:
Encoder output pulse phase selection
0: Increasing A-phase 90° in CCW or positive direction
1: Increasing A-phase 90° in CW or negative direction
Setting
value
Servo motor rotation direction
CCW or positive
direction
CW or negative
direction
0
A-phase
B-phase
A-phase
B-phase
1
A-phase
B-phase
A-phase
B-phase
0h
0 0 x _:
Encoder output pulse setting selection
0: Output pulse designation
1: Division ratio setting
_ _ x _ :
Encoder output pulse setting selection
0: Output pulse setting
When "_ 1 0 _" is set to this parameter, [AL. 37
Parameter error] will occur.
1: Division ratio setting
3: A-phase/B-phase pulse electronic gear setting
4: A/B-phase pulse through output setting
0h
_ x _ _ :
Selection of the encoders for encoder output pulse
This is used for selecting an encoder for servo amplifier
output.
0: Servo motor encoder
1: Load-side encoder
When "_ 1 0 _" is set to this parameter, [AL. 37
Parameter error] will occur.
0h
x _ _ _ :
For manufacturer setting
0h
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...