Part 3: Review on Replacement of MR-J3-_B_ with MR-J4-_B_
3 - 28
MR-J3-_B_
MR-J4-_B_
No.
Name and function
Initial
value
No.
Name and function
Initial
value
PB18 Low-pass filter setting
Set the low-pass filter.
Setting [Pr. PB023] (low-pass filter selection) to "_ _ 0 _"
automatically changes this parameter.
When [Pr. PB023] is set to "_ _ 1 _", this parameter can
be set manually.
3141 PB18 Same setting as MR-J3
3141
Low-pass filter setting
Set the low-pass filter.
The following shows a relation of a required parameter to
this parameter.
[Pr. PB23]
[Pr. PB18]
_ _ 0 _ (Initial value)
Automatic setting
_ _ 1 _
Setting value enabled
_ _ 2 _
Setting value disabled
PB19 Vibration suppression control vibration frequency setting
This parameter cannot be used in the speed control
mode.
Set the vibration frequency for vibration suppression
control to suppress low-frequency machine vibration,
such as enclosure vibration.
Setting [Pr. PB02] (vibration suppression control tuning
mode) to "_ _ _ 1"automatically changes this parameter.
When [Pr. PB02] is set to "_ _ _ 2", this parameter can
be set manually.
100.0 PB19 Same as MR-J3
100.0
Vibration suppression control 1 - Vibration frequency
Set the vibration frequency for vibration suppression
control 1 to suppress low-frequency machine vibration.
When "Vibration suppression control 1 tuning mode
selection" is set to "Automatic setting (_ _ _ 1)" in [Pr.
PB02], this parameter will be set automatically. Set
manually for "Manual setting (_ _ _ 2)".
PB20
Vibration suppression control resonance frequency
setting
This parameter cannot be used in the speed control
mode.
Set the resonance frequency for vibration suppression
control to suppress low frequency machine vibration,
such as enclosure vibration.
Setting [Pr. PB02] (vibration suppression control tuning
mode) to "_ _ _ 1" automatically changes this parameter.
When parameter No.PB02 is set to "_ _ _ 2", this
parameter can be set manually.
100.0
PB20
Same as MR-J3
100.0
Vibration suppression control 1 - Resonance frequency
Set the resonance frequency for vibration suppression
control 1 to suppress low-frequency machine vibration.
When "Vibration suppression control 1 tuning mode
selection" is set to "Automatic setting (_ _ _ 1)" in [Pr.
PB02], this parameter will be set automatically. Set
manually for "Manual setting (_ _ _ 2)".
PB21 For manufacturer setting
Do not change this value by any means.
0.00 PB21
Vibration
suppression
control 1 - Vibration frequency
damping
Set a damping of the vibration frequency for vibration
suppression control 1 to suppress low-frequency
machine vibration.
When "Vibration suppression control 1 tuning mode
selection" is set to "Automatic setting (_ _ _ 1)" in [Pr.
PB02], this parameter will be set automatically. Set
manually for "Manual setting (_ _ _ 2)".
0.00
PB22 For manufacturer setting
Do not change this value by any means.
0.00 PB22
Vibration
suppression
control 1 - Resonance frequency
damping
Set a damping of the resonance frequency for vibration
suppression control 1 to suppress low-frequency
machine vibration.
When "Vibration suppression control 1 tuning mode
selection" is set to "Automatic setting (_ _ _ 1)" in [Pr.
PB02], this parameter will be set automatically. Set
manually for "Manual setting (_ _ _ 2)".
0.00
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...