Part 2: Review on Replacement of MR-J3-_A_ with MR-J4-_A_
2 - 44
MR-J3-_A_
MR-J4-_A_
Control
mode
No.
Name and function
Initial
value
No.
Name and function
Initial
value
PC14 Analog monitor 1 output
Used to selection the signal provided to the analog
monitor 1 (MO1) output.
0 0 0 x:
Analog monitor 1 (MO1) output selection
Setting Item
0
Servo motor speed (8 V/max. speed)
1
Torque (8 V/max. torque) (Note 2)
2
Servo motor speed (+8 V/max. speed)
3
Torque (+8 V/max. torque) (Note 2)
4
Current command (8 V/max. current command
5
Command pulse frequency (10 V/1Mpps)
6
Droop pulses (10 V/100 pulses) (Note 1)
7
Droop pulses (10 V/1000 pulses) (Note 1)
8
Droop pulses (10 V/10000 pulses) (Note 1)
9
Droop pulses (10 V/100000 pulses) (Note 1)
A
Feedback position (10 V/1 Mpulses) (Note 1)
B
Feedback position (10 V/10 Mpulses) (Note 1)
C
Feedback position (10 V/100 Mpulses) (Note 1)
D
Bus voltage (8 V/400 V) (Note 3)
0000h
PC14 Analog monitor 1 output
_ _ x x:
Analog monitor 1 output selection
Select a signal to output to MO1 (Analog monitor 1).
Refer to table 2.6 for settings.
00h P
S
T
_ x _ _:
For manufacturer setting
0h
x _ _ _:
For manufacturer setting
0h
Table 2.6 Analog monitor setting value
(MR-J4-_A_(-RJ) 100 W or more)
Setting
value
Item
Operatio
n mode
(Note 1)
Standard
_ _ 0 0
(Linear) servo motor speed (±8 V/max. speed)
_ _ 0 1
Torque or thrust (±8 V/max. torque or max. thrust)
(Note 3)
_ _ 0 2
(Linear) servo motor speed (+8 V/max. speed)
_ _ 0 3
Torque or thrust (+8 V/max. torque or max. thrust)
(Note 3)
_ _ 0 4
Current command (±8 V/max. current command)
_ _ 0 5
Command pulse frequency (±10 V/±4 Mpulses/s)
_ _ 0 6
Servo motor-side droop pulses (±10 V/100 pulses)
(Note 2)
_ _ 0 7
Servo motor-side droop pulses (±10 V/1000 pulses)
(Note 2)
_ _ 0 8
Servo motor-side droop pulses (±10 V/10000 pulses)
(Note 2)
_ _ 0 9
Servo motor-side droop pulses (±10 V/100000 pulses)
(Note 2)
_ _ 0 A
Feedback position (±10 V/1 Mpulse) (Note 2)
_ _ 0 B
Feedback position (±10 V/10 Mpulses) (Note 2)
_ _ 0 C
Feedback position (±10 V/100 Mpulses) (Note 2)
_ _ 0 D
Bus voltage (200 V class and 100 V class: +8 V/400 V,
400 V class: +8 V/800 V)
_ _ 0 E
Speed command 2 (±8 V/max. speed)
_ _ 1 0
Load-side droop pulses (±10 V/100 pulses) (Note 2)
_ _ 1 1
Load-side droop pulses (±10 V/1000 pulses) (Note 2)
_ _ 1 2
Load-side droop pulses (±10 V/10000 pulses) (Note 2)
_ _ 1 3
Load-side droop pulses (±10 V/100000 pulses) (Note 2)
_ _ 1 4
Load-side droop pulses (±10 V/1 Mpulse) (Note 2)
_ _ 1 5
Servo motor-side/load-side position deviation
(±10 V/100000 pulses)
_ _ 1 6
Servo motor-side/load-side speed deviation
(±8 V/max. speed)
_ _ 1 7
Internal temperature of encoder (±10 V/±128 °C)
Note 1. Encoder pulse unit.
2. 8 V is outputted at the maximum torque.
However, when [Pr. PA11] [Pr. PA12] are
set to limit torque, 8 V is outputted at the
torque highly limited.
3. For 400 V class servo amplifier, the bus
voltage b8 V/800 V.
Note 1.
2.
3.
Items with
are available for each
operation mode.
Standard: Standard (semi closed loop
system) use of the rotary servo
motor
Encoder pulse unit
The larger value of [Pr. PA11] or [Pr. PA12]
will be the maximum torque.
PC15 Analog monitor 2 output
Used to selection the signal provided to the analog
monitor 2 (MO2) output.
0 0 0 x:
Select the analog monitor 2 (MO2) output
The settings are the same as those of [Pr. PC14]
0001h
PC15 Analog monitor 2 output
Analog monitor 2 output selection
_ _ x x:
Select a signal to output to MO2 (Analog monitor 2).
Refer to [Pr. PC14] for settings.
01h P
S
T
_ x _ _:
For manufacturer setting
0h
x _ _ _:
For manufacturer setting
0h
PC16 Electromagnetic
brake sequence output
Used to set the delay time (Tb) between electronic
brake interlock (MBR) and the base drive circuit is
shut-off.
100
PC16 Same as MR-J3
0 P
S
T
Analog monitor 2 output
Set the delay time between MBR (Electromagnetic
brake interlock) and the base drive circuit is shut-off.
Setting range: 0 to 1000
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...