Part 5: Review on Replacement of MR-J3-DU_ with MR-J4-DU_
5 - 38
5.1.2 Converter unit comparison of parameter details
POINT
Set a value to each "x" in the "Setting digit" columns.
MR-J3-CR55K/MR-J3-CR55K4 MR-CR55K/MR-CR55K4
No.
Name and function
Initial
value
No.
Name and function
Initial
value
PA01 Regenerative
option
Used to select the regenerative option
0 0 x x:
Select the regenerative option
00: No used
01: MR-RB139
02: MR-RB137 (3 pcs.)
11: MR-RB136-4
12: MR-RB138-4 (3 pcs.)
"01" and "02" are the set values for the MR-J3-CR55K
only, and "11" and "12" are those for the MR-J3-
CR55K4 only.
Incorrect setting will trigger [AL. 37 Parameter error].
0000h PA01 Regenerative
option
Select a regenerative option.
_ _ x x:
Incorrect setting will trigger [AL. 37 Parameter error].
00: Regenerative option is not used
When using the FR-BU2-(H) brake unit, select the
value.
01: MR-RB139
02: MR-RB137 (3 pcs.)
13: MR-RB137-4
14: MR-RB13V-4 (3 pcs.)
00h
_ x _ _:
For manufacturer setting
0h
x _ _ _:
For manufacturer setting
0h
PA02 Magnetic
contactor
drive output selection
Used to select the output of the magnetic contactor
drive power supply.
0 0 0 x:
Used to select the output of the magnetic contactor
drive power supply.
0: Disabled
1: Enabled
0001h PA02 Magnetic
contactor
drive output selection
Select the magnetic contactor drive output.
_ _ _ x
0: Disabled
1: Enabled
1h
_ _ x _:
For manufacturer setting
0h
_ x _ _:
For manufacturer setting
0h
x _ _ _:
For manufacturer setting
0h
PA08 Status display selection
Select a status display shown at power-on.
0 0 0 x:
Status display of converter unit display section at
power-on.
0: Status
1: Bus voltage
2: Effective load ratio
3: Peak load ratio
4: Regenerative load ratio
0000h
PA08
Status display selection
_ _ _ x:
Select a status display shown at power-on.
0: Status
1: Bus voltage
2: Effective load ratio
3: Peak load ratio
4: Regenerative load ratio
5: Unit power consumption 1
6: Unit total power consumption 1
7: Unit total power consumption 2
0h
_ _ x _:
For manufacturer setting
0h
_ x _ _:
For manufacturer setting
0h
x _ _ _:
For manufacturer setting
0h
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...