Part 5: Review on Replacement of MR-J3-DU_ with MR-J4-DU_
5 - 16
4.1.2 When magnetic contactor control connector (CNP1) is made invalid
POINT
●
When making CNP1 invalid, set "0000" in [Pr. PA02]. (Refer to Part: 5).
●
Always connect a protection coordination cable (MR-J3CDL05M). (For MR-J3-
DU_, always connect a terminal connector (MR-J3-TM) as well.) When they are
not connected properly, the servo-on may not be turned on.
●
Always turn on or off the control circuit power supplies of the converter unit and the
drive unit simultaneously.