Part 6: Common Reference Material
6 - 101
4.5.6 Disabling/enabling I/O devices (DIO)
You can disable inputs regardless of the I/O device status. When inputs are disabled, the input signals
(devices) are recognized as follows. However, EM2 (Forced stop 2), LSP (Forward rotation stroke end), and
LSN (Reverse rotation stroke end) cannot be disabled.
Signal Status
Input device (DI)
Off
External analog input signal
0 V
Pulse train input
None
(1) Disabling/enabling the input devices (DI), external analog input signals and pulse train inputs except
EM2 (Forced stop 2), LSP (Forward rotation stroke end), and LSN (Reverse rotation stroke end).
Transmit the following communication commands.
(a) Disabling
Command Data
No.
Data
[9] [0]
[0] [0]
1EA5
(b) Enabling
Command Data
No.
Data
[9] [0]
[1] [0]
1EA5
(2) Disabling/enabling the output devices (DO)
Transmit the following communication commands.
(a) Disabling
Command Data
No.
Data
[9] [0]
[0] [3]
1EA5
(b) Enabling
Command Data
No.
Data
[9] [0]
[1] [3]
1EA5
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...