Part 4: Replacement of MR-J3W-_B with MR-J4W2-_B
4 - 22
3.7.2 Parameter comparison list
POINT
The parameter whose symbol preceded by * can be validated with the following
conditions.
* : Turn off the power and then on again, or reset the controller after setting the
parameter.
**: Turn off the power and then on again after setting the parameter.
How to set parameters
Each: Set parameters for each axis of A and B.
Common: Set parameters for common axis of A and B. Be sure to set the same
value to all axes.
The same values are set as default for all axes.
Setting an out of range value to each parameter will trigger [AL. 37 Parameter
error].
MR-J3W-_B
parameters MR-J4W2-_B
parameters
No. Symbol
Parameter
name
Setting
Factory
setting
Customer
setting
value
No. Symbol
Parameter
name
Setting
Factory
setting
Customer
setting
value
PA01 **STY Control
mode
Each
axis
0000h
PA01 **STY Operation
mode
Each
axis
1000h
PA02 **REG Regenerative
option
Common 0000h
PA02 **REG Regenerative option
Common 0000h
PA03 *ABS
Absolute position detection
system
Each
axis
0000h
PA03 *ABS
Absolute position detection
system
Each
axis
0000h
PA04 *AOP1 Function selection A-1
Common 0000h
PA04 *AOP1 Function selection A-1
Common 2000h
PA05
This parameter is not used.
Do not change the value.
0
PA05
For manufacturer setting
10000
PA06 1
PA06
1
PA07 1
PA07
1
PA08
ATU
Auto tuning mode
Each
axis
0001h
PA08 ATU
Auto tuning mode
Each
axis
0001h
PA09
RSP
Auto tuning response
Each
axis
12
PA09 RSP
Auto tuning response
Each
axis
16
PA10 INP In-position
range
Each
axis
100
PA10 INP
In-position range
Each
axis
1600
PA11
This parameter is not used.
Do not change the value.
1000.0 PA11
For manufacturer setting
1000.0
PA12 1000.0
PA12
1000.0
PA13 0000h
PA13
0000h
PA14 *POL
Rotation direction selection
Each
axis
0
PA14 *POL
Rotation direction
selection/travel direction
selection
Each
axis
0
PA15
*ENR
Encoder output pulses
Each
axis
4000
PA15
*ENR
Encoder output pulses
Each
axis
4000
PA16 *ENR2 Encoder output pulses 2
Each
axis
0
PA16 *ENR2 Encoder output pulses 2
Each
axis
1
PA17
This parameter is not used.
Do not change the value.
0000h
PA17
For manufacturer setting
0000h
PA18 0000h
PA18
0000h
PA19 *BLK
Parameter write inhibit
Each
axis
000Bh
PA19 *BLK
Parameter writing inhibit
Each
axis
00ABh
PB01 FILT
Adaptive tuning mode
(Adaptive filter II)
Each
axis
0000h
PB01 FILT
Adaptive tuning mode
(adaptive filter II)
Each
axis
0000h
PB02 VRFT
Vibration suppression
control tuning mode
(advanced vibration
suppression control)
Each
axis
0000h
PB02 VRFT
Vibration suppression control
tuning mode (advanced
vibration suppression control
II)
Each
axis
0000h
PB03
This parameter is not used.
Do not change the value.
0
PB03 TFBGN
Torque feedback loop gain
Each
axis
18000
PB04 FFC
Feed forward gain
Each
axis
0
PB04 FFC
Feed forward gain
Each
axis
0
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...