Part 2: Review on Replacement of MR-J3-_A_ with MR-J4-_A_
2 - 42
MR-J3-_A_
MR-J4-_A_
Control
mode
No.
Name and function
Initial
value
No.
Name and function
Initial
value
PC05
Internal speed command 1
Used to set speed 1 of internal speed commands.
100 PC05
Same as MR-J3
100 S
Internal speed command 1
Set the speed 1 of internal speed commands.
Setting range: 0 to permissible instantaneous speed
Internal speed limit 1
Used to set speed 1 of internal speed limits.
Internal speed limit 1
Set the speed 1 of internal speed limits.
Setting range: 0 to permissible instantaneous speed
T
PC06
Internal speed command 2
Used to set speed 2 of internal speed commands.
500 PC06
Same as MR-J3
500 S
Internal speed command 2
Set the speed 2 of internal speed commands.
Setting range: 0 to permissible instantaneous speed
Internal speed limit 2
Used to set speed 2 of internal speed limits.
Internal speed limit 2
Set the speed 2 of internal speed limits.
Setting range: 0 to permissible instantaneous speed
T
PC07
Internal speed command 3
Used to set speed 3 of internal speed commands.
1000 PC07 Same as MR-J3
1000 S
Internal speed command 3
Set the speed 3 of internal speed commands.
Setting range: 0 to permissible instantaneous speed
Internal speed limit 3
Used to set speed 3 of internal speed limits.
Internal speed limit 3
Set speed 3 of internal speed limits.
Setting range: 0 to permissible instantaneous speed
T
PC08
Internal speed command 4
Used to set speed 4 of internal speed commands.
200 PC08
Same as MR-J3
200 S
Internal speed command 4
Set the speed 4 of internal speed commands.
Setting range: 0 to permissible instantaneous speed
Internal speed limit 4
Used to set speed 4 of internal speed limits.
Internal speed limit 4
Set the speed 4 of internal speed limits.
Setting range: 0 to permissible instantaneous speed
T
PC09
Internal speed command 5
Used to set speed 5 of internal speed commands.
300 PC09
Same as MR-J3
300 S
Internal speed command 5
Set the speed 5 of internal speed commands.
Setting range: 0 to permissible instantaneous speed
Internal speed limit 5
Used to set speed 5 of internal speed limits.
Internal speed limit 5
Set the speed 5 of internal speed limits.
Setting range: 0 to permissible instantaneous speed
T
PC10 Internal speed command 6
Used to set speed 6 of internal speed commands.
500 PC10
Same as MR-J3
500 S
Internal speed command 6
Set the speed 6 of internal speed commands.
Setting range: 0 to permissible instantaneous speed
Internal speed limit 6
Used to set speed 6 of internal speed limits.
I
nternal speed limit 6
Set the speed 6 of internal speed limits.
Setting range: 0 to permissible instantaneous speed
T
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...