(b) When connecting two brake units to a resistance regeneration converter unit
POINT
To use brake units with a parallel connection, use two sets of FR-BU2-(H) brake
unit. Combination with other brake unit results in alarm occurrence or
malfunction.
Always connect the terminals for master/slave (MSG to MSG, SD to SD)
between the two brake units.
Do not connect as follows.
N/-
P/+
Brake unit
Brake unit
Converter unit
L+
L-
N/-
P/+
Connecting two cables to L+ and L-
terminals
N/-
P/+
Brake unit
Brake unit
Converter unit
L+
L-
N/-
P/+
Passing wiring