Part 4: Replacement of MR-J3W-_B with MR-J4W2-_B
4 - 47
MR-J3W-_B MR-J4W2-_B
No.
Name and function
Initial
value
No.
Name and function
Initial
value
PD08 This parameter is not used. Do not change the value.
0004h
PD08 Output device selection 2
You can assign any output device to the CN3-24 pin for
each axis. CINP (AND in-position) is assigned to the all
axes in the initial setting.
The devices that can be assigned and the setting
method are the same as in [Pr. PD07].
_ _ x x:
Device selection
Refer to table 4.6 in [Pr. PD07] for settings.
04h
_ x _ _:
All-axis output condition selection
0: AND output
When all axes of A and B meet a condition, the device
will be enabled (on or off).
1: OR output
When all axes of A or B meet a condition, the device
will be enabled (on or off).
The digit will be enabled when "All axes (0 _ _ _)" is
selected.
0h
x _ _ _:
Output axis selection
0: All axes
1: A-axis
2: B-axis
0h
PD09 Output signal device selection 3 (CN3-11 for A-axis and
CN3-24 for B-axis)
Any input signal can be assigned to the CN3-11 pin for
A-axis and CN3-24 pin for B-axis. In the factory setting,
ALM-A/ALM-B is assigned.
The devices that can be assigned and the setting method
are the same as in [Pr. PD07].
0 0 x x:
Select the output device of the CN3-11 pin for Aaxis
and CN3-24 pin for B-axis.
0003h
PD09 Output device selection 3
You can assign any output device to the CN3-11 pin for
each axis. CALM (AND malfunction) is assigned to the
all axes in the initial setting.
The devices that can be assigned and the setting
method are the same as in [Pr. PD07].
_ _ x x:
Device selection
Refer to table 4.6 in [Pr. PD07] for settings.
03h
_ x _ _:
All-axis output condition selection
0: AND output
When all axes of A and B meet a condition, the device
will be enabled (on or off).
1: OR output
When each axis of A or B meet a condition, the device
will be enabled (on or off).
The digit will be enabled when "All axes (0 _ _ _)" is
selected.
0h
x _ _ _:
Output axis selection
0: All axes
1: A-axis
2: B-axis
0h
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...