Part 6: Common Reference Material
6 - 94
(4) Reading the setting
The following shows how to read the parameter setting. Specify a parameter group in advance. (Refer to
(1) of this section.)
(a) Transmission
Transmit the command [1] [5] and the data No. corresponding to the parameter No [0] [1] to [F] [F].
(Refer of section 4.4.1.)
The data No. is expressed in hexadecimal. The decimal equivalent of the data No. value
corresponds to the parameter No.
(b) Return
The slave station returns the data and processing information of the parameter No. requested.
0
Display type
0: Data is used unchanged in hexadecimal.
1: Data must be converted into decimal.
Parameter writing type
0: Enabled after writing
1: Enabled when power is cycled after writing
Decimal point position
0: No decimal point
1: First least significant digit
2: Second least significant digit
3: Third least significant digit
4: Forth least significant digit
5: Fifth least significant digit
Data is transferred in hexadecimal.
0 0 0
Sign
0: Sign
1: No sign
0
Readable/unreadable
0: Readable
1: Unreadable
For example, data "00120000270F" means 999.9 (decimal display format) and data
"000000003ABC" means 3ABC (hexadecimal display format).
When the display type is "0" (hexadecimal) and the decimal point position is other than 0, the display
type is a special hexadecimal display format and "F" of the data value is handled as a blank. Data
"0001FFFFF053" means 053 (special hexadecimal display format).
"000000000000" is transferred when the parameter that was read is the one inaccessible for
reference in the parameter writing inhibit setting of [Pr. PA19].
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...