Part 2: Review on Replacement of MR-J3-_A_ with MR-J4-_A_
2 - 36
MR-J3-_A_
MR-J4-_A_
Control
mode
No.
Name and function
Initial
value
No.
Name and function
Initial
value
PB18 Low-pass filter setting
Set the low-pass filter.
Setting [Pr. PB23] (low-pass filter selection) to "_ _
0 _" automatically changes this parameter.
When [Pr. PB23] is set to "_ _ 1 _ ", this parameter
can be set manually.
3141 PB18
Same as MR-J3
3141 P
S
Low-pass filter setting
Set the low-pass filter.
The following shows a relation of a required
parameter to this parameter.
[Pr. PB23]
[Pr. PB18]
_ _ 0_ (Initial value)
Automatic setting
_ _ 1 _
Setting value
enabled
_ _ 2 _
Setting value
disabled
Setting is not necessary because this parameter is
automatically set.
PB19 Vibration
suppression
control vibration frequency
setting
Set the vibration frequency for vibration suppression
control to suppress low-frequency machine
vibration, such as enclosure vibration.
Setting [Pr. PB02] (vibration suppression control
tuning mode) to "_ _ _ 1" automatically changes this
parameter. When [Pr. PB02] is set to "_ _ _ 2", this
parameter can be set manually.
100.0 PB19
Same as MR-J3
100.0 P
Vibration suppression control 1 - Vibration frequency
Set the vibration frequency for vibration suppression
control 1 to suppress low-frequency machine
vibration.
When "Vibration suppression control 1 tuning mode
selection" is set to "Automatic setting (_ _ _ 1)" in
[Pr. PB02], this parameter will be set automatically.
Set manually for "Manual setting (_ _ _ 2)".
Setting range: 0.1 to 300.0
PB20 Vibration
suppression
control resonance frequency
setting
Set the resonance frequency for vibration
suppression control to suppress low-frequency
machine vibration, such as enclosure vibration.
Setting [Pr. PB02] (vibration suppression control
tuning mode) to "_ _ _ 1" automatically changes this
parameter. When [Pr. PB02] is set to "_ _ _ 2", this
parameter can be set manually.
PB20
PB20
Same as MR-J3
100.0 P
Vibration suppression control 1 - Resonance
frequency
Set the resonance frequency for vibration
suppression control 1 to suppress low-frequency
machine vibration.
[When "Vibration suppression control 1 tuning mode
selection" is set to "Automatic setting (_ _ _ 1)" in
[Pr. PB02], this parameter will be set automatically.
Set manually for "Manual setting (_ _ _ 2)".
Setting range: 0.1 to 300.0
PB21 For manufacturer setting
Do not change this value by any means.
0.00 PB21
Vibration suppression control 1 - Vibration frequency
damping
Set a damping of the vibration frequency for
vibration suppression control 1 to suppress low-
frequency machine vibration.
When "Vibration suppression control 1 tuning mode
selection" is set to "Automatic setting (_ _ _ 1)" in
[Pr. PB02], this parameter will be set automatically.
Set manually for "Manual setting (_ _ _ 2)".
Setting range: 0.00 to 0.30
0.00 P
PB22 For manufacturer setting
Do not change this value by any means.
0.00 PB22
Vibration suppression control 1 - Resonance
frequency damping
Set a damping of the resonance frequency for
vibration suppression control 1 to suppress low-
frequency machine vibration.
When "Vibration suppression control 1 tuning mode
selection" is set to "Automatic setting (_ _ _ 1)" in
[Pr. PB02], this parameter will be set automatically.
Set manually for "Manual setting (_ _ _ 2)".
Setting range: 0.00 to 0.30
0.00 P
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...