Part 8: Review on Replacement of Optional Peripheral Equipment
8 - 19
4.1.2 MR-J4 series power supply wire size
POINT
To comply with the IEC/EN/UL/CSA standard, use the wires shown in the
instruction manuals of the servo amplifier in use for wiring. To comply with other
standards, use a wire that is complied with each standard.
Selection conditions of wire size are as follows.
Construction condition: Single wire set in midair
Wire length: 30 m or less
The following diagram shows the wires used for wiring. Use the wires given in this section or equivalent.
5) Power regeneration converter lead
Power regeneration
converter
N-
3) Regenerative option lead
Regenerative option
2) Control circuit power supply lead
C
P+
L
L
L
L1
L2
1) Main circuit power supply lead
Power supply
Servo amplifier
U
V
W
M
4) Servo motor power supply lead
Summary of Contents for Melservo MR-J3-100B