Part 4: Replacement of MR-J3W-_B with MR-J4W2-_B
4 - 25
MR-J3W-_B parameters
MR-J4W2-_B parameters
No. Symbol
Parameter
name
Setting
Factory
setting
Customer
setting
value
No. Symbol
Parameter
name
Setting
Factory
setting
Customer
setting
value
PC22
This parameter is not used.
Do not change the value.
0000h
PC22
For manufacturer setting
0
PC23 0000h
PC23
0000h
PC24
0000h
PC24 RSBR Forced
stop
deceleration
time constant
Each
axis
100
PC25 0000h
PC25
For manufacturer setting
0
PC26 0000h
PC26
0000h
PC27
0000h
PC27 **COP9 Function
selection
C-9
Each
axis
0000h
PC28
0000h
PC28 For
manufacturer
setting
0000h
PC29
0000h
PC29 *COPB Function selection C-B
Each
axis
0000h
PC30
0000h
PC30 For
manufacturer
setting
0
PC31
0000h
PC31 RSUP1 Vertical axis freefall
prevention compensation
amount
Each
axis
0
PC32
0000h
PC32 For
manufacturer
setting
0000h
PD01
0000h
PD01 For
manufacturer setting
0000h
PD02
0000h
PD02 *DIA2 Input signal automatic on
selection 2
Each
axis
0000h
PD03 0020h
PD03
For manufacturer setting
0020h
PD04 0021h
PD04
0021h
PD05 0022h
PD05
0022h
PD06 0000h
PD06
0000h
PD07
*D01
Output signal device
selection 1 (CN3-12 for A-
axis and CN3-25 for B-axis)
Each
axis
0005h
PD07
*DO1
Output device selection 1
Each
axis
0005h
PD08 This
parameter is not used.
Do not change the value.
0004h
PD08
*DO2
Output device selection 2
Common 0004h
PD09
*D03
Output signal device
selection 3 (CN3-11 for A-
axis and CN3-24 for B-axis)
Each
axis
0003h
PD09
*DO3
Output device selection 3
Common 0003h
PD10 This parameter is not used.
Do not change the value.
0000h
PD10 For
manufacturer setting
0000h
PD11
0004h
PD11 *DIF Input filter setting (Note)
Common 0004h
PD12
0000h
PD12 *DOP1 Function
selection
D-1
Each
axis
0000h
PD13
0000h
PD13 For
manufacturer setting
0000h
PD14 *DOP3 Function selection D-3
Each
axis
0000h
PD14 *DOP3 Function
selection
D-3
Each
axis
0000h
PD15 This parameter is not used.
Do not change the value.
0000h
PD15
For manufacturer setting
0000h
PD16 0000h
PD16 0000h
PD17 0000h
PD17 0000h
PD18 0000h
PD18 0000h
PD19 0000h
PD19 0000h
PD20 0
PD20 0
PD21 0
PD21 0
PD22 0
PD22 0
PD23 0
PD23 0
PD24 0000h
PD24 0000h
PD25 0000h
PD25 0000h
PD26 0000h
PD26 0000h
PD27 0000h
PD27 0000h
PD28 0000h
PD28
0000h
PD29 0000h
PD29
0000h
PD30 0000h
PD30
0
PD31 0000h
PD31
0
PD32 0000h
PD32
0
Note. Refer to the servo system controller instruction manual for the setting.
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...