Part 3: Review on Replacement of MR-J3-_B_ with MR-J4-_B_
3 - 35
MR-J3-_B_
MR-J4-_B_
No.
Name and function
Initial
value
No.
Name and function
Initial
value
PC04
Function selection C-1
Select the encoder cable communication system
selection.
x 0 0 0:
Encoder cable communication system selection
0: Two-wire type
1: Four-wire type
Incorrect setting will result in an [AL.16 encoder alarm 1].
0000h
PC04
Same as MR-J3
Function selection C-1
Select the encoder cable communication method
selection.
_ _ _ x:
For manufacturer setting
0h
_ _ x _ :
For manufacturer setting
0h
_ x _ _ :
For manufacturer setting
0h
x _ _ _ :
Encoder cable communication method selection
0: Two-wire type
1: Four-wire type
When using an encoder of A/B/Z-phase differential
output method, set "0".
Incorrect setting will result in [AL. 16 Encoder initial
communication error 1]. or [AL. 20 Encoder initial
communication error 1] will occur.
0h
PC05 Function selection C-2
Motor-less operation select.
0 0 0 x:
Motor-less operation select.
0: Valid
1: Invalid
0000h PC05 Same setting as MR-J3
Function selection C-2
Set the motor-less operation.
_ _ _ x:
Motor-less operation selection
0: Disabled
1: Enabled
0h
_ _ x _ :
For manufacturer setting
0h
_ x _ _ :
For manufacturer setting
0h
x _ _ _ :
[AL. 9B Error excessive warning] selection
0: [AL. 9B Error excessive warning] disabled
1: [AL. 9B Error excessive warning] enabled
The setting of this digit is used by servo amplifier with
software version B4 or later.
0h
PC06
Function selection C-3
This parameter cannot be used in the speed control
mode or in the torque control mode.
Select the error excessive alarm level setting for
[Pr. PC01]
x 0 0 0:
Error excessive alarm level setting selection
0: 1 [rev] unit
1: 0.1 [rev] unit
2: 0.01 [rev] unit
3: 0.001 [rev] unit
This parameter is available to software version B1 or
later.
Check the software version using Setup software
(SETUP221E).
0000h PC06 Same as MR-J3
Function selection C-3
Select units for error excessive alarm level setting with
[Pr. PC01]. The parameter is not available in the speed
control mode and torque control mode.
_ _ _ x:
For manufacturer setting
0h
_ _ x _ :
For manufacturer setting
0h
_ x _ _ :
For manufacturer setting
0h
x _ _ _ :
Error excessive alarm/error excessive warning level unit
selection
0: Per 1 rev or 1 mm
1: Per 0.1 rev or 0.1 mm
2: Per 0.01 rev or 0.01 mm
3: Per 0.001 rev or 0.001 mm
0h
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...