Part 2: Review on Replacement of MR-J3-_A_ with MR-J4-_A_
2 - 49
MR-J3-_A_
MR-J4-_A_
Control
mode
No.
Name and function
Initial
value
No.
Name and function
Initial
value
PC32 Command pulse multiplying factor numerator 2
Available when the [Pr. PA05] is set to "0".
1
PC32 Commanded pulse multiplication numerator 2
To enable the parameter, select "Electronic gear (0
_ _ _)" or "J3 electronic gear setting value
compatibility mode (2 _ _ _)" of "Electronic gear
selection" in [Pr. PA21].
Setting range: 1 to 16777215
1 P
PC33
Command pulse multiplying factor numerator 3
Available when the [Pr. PA05] is set to "0".
1 PC33
Commanded pulse multiplication numerator 3
To enable the parameter, select "Electronic gear (0
_ _ _)" or "J3 electronic gear setting value
compatibility mode (2 _ _ _)" of "Electronic gear
selection" in [Pr. PA21].
Setting range: 1 to 16777215
1 P
PC34
Command pulse multiplying factor numerator 4
Available when the [Pr. PA05] is set to "0".
1 PC34
Commanded pulse multiplication numerator 4
To enable the parameter, select "Electronic gear (0
_ _ _)" or "J3 electronic gear setting value
compatibility mode (2 _ _ _)" of "Electronic gear
selection" in [Pr. PA21].
Setting range: 1 to 16777215
1
P
PC35 Internal torque limit 2
Set this parameter to limit servo motor torque on the
assumption that the maximum torque is 100 [%].
When 0 is set, torque is not produced.
When torque is output in analog monitor output, this
set value is the maximum output voltage (8 V).
100.0
PC35 Internal torque limit 2
Set the parameter on the assumption that the
maximum torque is 100.0%.
The parameter is for limiting the torque of the servo
motor.
No torque is generated when this parameter is set to
"0.0".
When TL1 (Internal torque limit selection) is turned
on, Internal torque limits 1 and 2 are compared and
the lower value will be enabled.
Setting range: 0.0 to 100.0
100.0 P
S
T
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...