Part 4: Replacement of MR-J3W-_B with MR-J4W2-_B
4 - 39
MR-J3W-_B MR-J4W2-_B
No.
Name and function
Initial
value
No.
Name and function
Initial
value
PB45 This parameter is not used. Do not change the value.
0000h
PB45 Command notch filter
Set the command notch filter.
_ _ x x:
Command notch filter setting frequency selection
Refer to table 4.4 for the relation of setting values to
frequency.
00h
_ x _ _ :
Notch depth selection
Refer to table 4.5 for details.
0h
x _ _ _ :
For manufacturer setting
0h
Table 4.4 Command notch filter setting frequency
selection
Setting
value
Frequency
[Hz]
Setting
value
Frequency
[Hz]
Setting
value
Frequency
[Hz]
_ _ 0 0
Disabled
_ _ 2 0
70
_ _ 4 0
17.6
_ _ 0 1
2250
_ _ 2 1
66
_ _ 4 1
16.5
_ _ 0 2
1125
_ _ 2 2
62
_ _ 4 2
15.6
_ _ 0 3
750
_ _ 2 3
59
_ _ 4 3
14.8
_ _ 0 4
562
_ _ 2 4
56
_ _ 4 4
14.1
_ _ 0 5
450
_ _ 2 5
53
_ _ 4 5
13.4
_ _ 0 6
375
_ _ 2 6
51
_ _ 4 6
12.8
_ _ 0 7
321
_ _ 2 7
48
_ _ 4 7
12.2
_ _ 0 8
281
_ _ 2 8
46
_ _ 4 8
11.7
_ _ 0 9
250
_ _ 2 9
45
_ _ 4 9
11.3
_ _ 0 A
225
_ _ 2 A
43
_ _ 4 A
10.8
_ _ 0 B
204
_ _ 2 B
41
_ _ 4 B
10.4
_ _ 0 C
187
_ _ 2 C
40
_ _ 4 C
10
_ _ 0 D
173
_ _ 2 D
38
_ _ 4 D
9.7
_ _ 0 E
160
_ _ 2 E
37
_ _ 4 E
9.4
_ _ 0 F
150
_ _ 2 F
36
_ _ 4 F
9.1
_ _ 1 0
140
_ _ 3 0
35.2
_ _ 5 0
8.8
_ _ 1 1
132
_ _ 3 1
33.1
_ _ 5 1
8.3
_ _ 1 2
125
_ _ 3 2
31.3
_ _ 5 2
7.8
_ _ 1 3
118
_ _ 3 3
29.6
_ _ 5 3
7.4
_ _ 1 4
112
_ _ 3 4
28.1
_ _ 5 4
7.0
_ _ 1 5
107
_ _ 3 5
26.8
_ _ 5 5
6.7
_ _ 1 6
102
_ _ 3 6
25.6
_ _ 5 6
6.4
_ _ 1 7
97
_ _ 3 7
24.5
_ _ 5 7
6.1
_ _ 1 8
93
_ _ 3 8
23.4
_ _ 5 8
5.9
_ _ 1 9
90
_ _ 3 9
22.5
_ _ 5 9
5.6
_ _ 1 A
86
_ _ 3 A
21.6
_ _ 5 A
5.4
_ _ 1 B
83
_ _ 3 B
20.8
_ _ 5 B
5.2
_ _ 1 C
80
_ _ 3 C
20.1
_ _ 5 C
5.0
_ _ 1 D
77
_ _ 3 D
19.4
_ _ 5 D
4.9
_ _ 1 E
75
_ _ 3 E
18.8
_ _ 5 E
4.7
_ _ 1 F
72
_ _ 3 F
18.2
_ _ 5 F
4.5
Table 4.5 Notch depth selection
Setting value
Depth [dB]
Setting value
Depth [dB]
_ 0 _ _
-40.0
_ 8 _ _
-6.0
_ 1 _ _
-24.1
_ 9 _ _
-5.0
_ 2 _ _
-18.1
_ A _ _
-4.1
_ 3 _ _
-14.5
_ B _ _
-3.3
_ 4 _ _
-12.0
_ C _ _
-2.5
_ 5 _ _
-10.1
_ D _ _
-1.8
_ 6 _ _
-8.5
_ E _ _
-1.2
_ 7 _ _
-7.2
_ F _ _
-0.6
PC01 Error excessive alarm level
This parameter cannot be used in the speed control
mode and the torque control mode.
Used to set the error excessive alarm level with rotation
amount of servo motor.
When "0" is set in this parameter, the alarm level is three
rotations.
When a value other than "0" is set, the alarm
level is the rotation number of the set value.
However,
the alarm level stays at 200 rotations even if a value
exceeding "200" is set.
Note. Setting can be changed in [Pr. PC06].
0
PC01 Error excessive alarm level
Set an error excessive alarm level.
Set this per rev. for rotary servo motors and direct drive
motors. Setting "0" will be 3 rev. Setting over 200 rev will
be clamped with 200 rev.
Note. Setting can be changed in [Pr. PC06].
0
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...