Part 6: Common Reference Material
6 - 70
Parameter
No.
Name Initial
value
Setting
value
Description
PD32
Master-slave operation - Speed limit
adjusted value on slave
- -
Master-slave operation - Speed limit adjusted value on
slave
Use MR-J4-_B_ with the software version A8 or later to
use this function.
A parameter error will occur when MR-J4-_B_ with the
software version A7 or earlier is used.
Note. For items that have no setting value listed in the table, refer to "Part 3: Review on Replacement of MR-J3-_B_ with MR-J4-_B_",
"Part 4: Review on Replacement of MR-J3W-_B_ with MR-J4W-_B_"..
(2) MR-J3W-_B => MR-J4W2-_B
Parameter
No.
Name Initial
value
Setting
value
Description
PC01
Error excessive alarm level
-
-
Although the initial values of the MR-J3-_B_ and MR-J3W-
_B are different, the same operation is performed.
Also, the setting ranges are different. Check the setting
values and change them as necessary.
PC03
Encoder output pulse selection
-
-
Although the initial values of the MR-J3-_B_ and MR-J3W-
_B are different, the values are overwritten with the setting
values on the controller side (parameter of MR-J3-_B_)
after power-on.
Note. For items that have no setting value listed in the table, refer to "Part 4: Review on Replacement of MR-J3W-_B with MR-J4W2-
_B".
(3) MR-J3W-0303BN6 => MR-J4W2-0303B6
Parameter
No.
Name
Initial
value
Setting
value
Description
PC05
Function selection C-2
-
-
Select a voltage to be connected to the main circuit power
supply with an MR-J4W2-0303B6 servo amplifier.
Main circuit power supply the characteristics of the servo
motor vary depending on whether 48 V DC or 24 V DC is
used.
[Pr. PC05]: "_ 0 _ _" DC 48 V (Initial value)
"_ 1 _ _" DC 24 V
Po04
Main circuit power supply selection
-
-
The setting of this digit in the J3 compatibility mode is the
same as the MR-J3W-0303BN6 servo amplifier. Set it with
[Pr. Po04].
Main circuit power supply the characteristics of the servo
motor vary depending on whether 48 V DC or 24 V DC is
used.
[Pr. Po04]: "0 _ _ _" DC 48 V (Initial value)
"1 _ _ _" DC 24 V
Note. For items that have no setting value listed in the table, refer to "Part 4: Review on Replacement of MR-J3W-_B with MR-J4W2-
_B".
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...