Part 4: Replacement of MR-J3W-_B with MR-J4W2-_B
4 - 31
MR-J3W-_B MR-J4W2-_B
No.
Name and function
Initial
value
No.
Name and function
Initial
value
PB02 Vibration suppression control tuning mode (advanced
vibration suppression control)
Used to set the tuning mode for the vibration
suppression control.
0 0 0 x:
Vibration suppression control tuning mode
0: Invalid
1: Cannot be set
2: Manual setting
If "_ _ _ 1" is set for this parameter, it is automatically
rewritten as "_ _ _0".
0000h PB02 Vibration
suppression
control tuning mode (advanced
vibration suppression control II)
This is used to set the vibration suppression control
tuning.
All axes cannot be simultaneously enabled for this
function. Set for each axis to use.
_ _ _ x:
Vibration suppression control 1 tuning mode selection
Select the tuning mode of the vibration suppression
control 1.
0: Disabled
1: Automatic setting
2: Manual setting
0h
_ _ x _ :
Vibration suppression control 2 tuning mode selection
Select the tuning mode of the vibration suppression
control 2. To enable the digit, select "3 inertia mode (_ _
_ 1)" of "Vibration suppression mode selection" in [Pr.
PA24 Function selection A-4].
0: Disabled
1: Automatic setting
2: Manual setting
0h
_ x _ _ :
For manufacturer setting
0h
x _ _ _ :
For manufacturer setting
0h
PB03 This parameter is not used. Do not change the value.
0
PB03 Torque feedback loop gain
Set a torque feedback loop gain in the continuous
operation to torque control mode.
Decreasing the setting value will also decrease a
collision load during continuous operation to torque
control mode.
Setting a value less than 6 rad/s will be 6 rad/s.
18000
PB04 Feed forward gain
This parameter cannot be used in the speed control
mode.
Set the feed forward gain. When the setting is 100%, the
droop pulses during operation at constant speed are
nearly zero. However, sudden acceleration/deceleration
will increase the overshoot. As a guideline, when the
feed forward gain setting is 100%, set 1s or more as the
acceleration time constant up to the rated speed.
0 PB04
Feed forward gain
Set the feed forward gain.
When the setting is 100%, the droop pulses during
operation at constant speed are nearly zero. However,
sudden acceleration/deceleration will increase the
overshoot. As a guideline, when the feed forward gain
setting is 100%, set 1 s or more as the acceleration time
constant up to the rated speed.
0
PB06 Load to motor inertia moment ratio
Used to set the ratio of the load inertia moment to the
servo motor shaft inertia moment. When auto tuning
mode 1 and interpolation mode is selected, the result of
auto tuning is automatically used.
In this case, it varies between 0 and 100.0.
When [Pr. PA08] is set to "_ _ _ 2" or "_ _ _ 3" , this
parameter can be set manually.
7.0
PB06 Load to motor inertia ratio/load to motor mass ratio
Set a load to motor inertia ratio or load to motor mass
ratio. Setting a value considerably different from the
actual load moment of inertia or load mass may cause
an unexpected operation such as an overshoot.
The setting of the parameter will be the automatic setting
or manual setting depending on the [Pr. PA08] setting.
Refer to the following table for details. When the
parameter is automatic setting, the value will vary
between 0.00 and 100.00.
Pr. PA08
This parameter
_ _ _ 0 (2 gain adjustment mode 1
(interpolation mode))
Automatic setting
_ _ _ 1 (Auto tuning mode 1)
_ _ _ 2 (Auto tuning mode 2)
Manual setting
_ _ _ 3 (Manual mode)
_ _ _ 4 (2 gain adjustment mode 2)
7.00
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...