Part 8: Review on Replacement of Optional Peripheral Equipment
8 - 13
Application MR-J3
series MR-J4
series
Compatibility
(Note
6
)
Note
Servo amplifier power
connector
(1 kW or less)
CNP1 54928-0670
06JFAT-SAXGDK-H7.5
(Note
2
)
Connector shape is changed
because the manufacturer is
changed.
( ) is for MR-J3-200_(-RT).
CNP2 54927-0520
05JFAT-SAXGDK-H5.0
(Note
2
)
CNP3 54928-0370
03JFAT-SAXGDK-H7.5
(Note
2
)
Servo amplifier power
connector
(2 kW)
CNP1
721-207/026-000
(PC4/6-STF-7.62-CRWH)
06JFAT-SAXGFK-XL
(Note
2
)
CNP2
721-205/026-000
(54927-0520)
05JFAT-SAXGDK-H5.0
(Note
2
)
CNP3
721-203/026-000
(PC4/3-STF-7.62-CRWH)
03JFAT-SAXGFK-XL
(Note
2
)
Servo amplifier power
connector
(3.5 kW)
CNP1 PC4/6-STF-7.62-CRWH 06JFAT-SAXGFK-XL
(Note
2
)
CNP2 54927-0520
05JFAT-SAXGDK-H5.0
(Note
2
)
CNP3 PC4/3-STF-7.62-CRWH 03JFAT-SAXGFK-XL
(Note
2
)
CN5 communication cable
MR-J3USBCBL3M
Use the same combination.
Battery for junction battery cable
MR-J3BTCBL03M MR-BT6VCBL03M (Note
3)
Use the dedicated battery
of each series.
Monitor cable
MR-J3CN6CBL1M
Use the same combination.
Protection coordination cable
MR-J3CDL05M
Use the same combination.
(30 kW or more)
CN40/CN40A connector set
MR-J2CN1-A
Use the same combination.
Termination connector
MR-J3-TM
Not required
Magnetic contactor wiring
connector
(Note 4)
Use the same combination.
Socket:
GFKC 2.5/2-STF-7.62
Digital I/O connector
Use the same combination.
connector:
17JE23090-02(D8A)K11-
CG
STO
cable
MR-D05UDL3M-B
(Note
5)
When not using the STO
function, attach the short-
circuit connector came with
the servo amplifier to CN8.
Note 1. When using 15 kW or more HG-JR 1000 r/min series or 22 kW or more HG-JR 1500 r/min series, replace with the MR-
ENECBL_M-H-MTH cable or MR-ENECNS connector set.
2. These replacement models do not have compatibility in mounting. The power connector is supplied with a servo amplifier for
MR-J4 series. Replace the existing connectors with the ones supplied with the servo amplifier.
3. Use the dedicated battery of each series.
4. Supplied with converter unit.
5. MR-D05UDL3M-B is in production.
6.
: Compatible,
△
: Compatible with condition, ×: Not compatible
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...