MR-J3-CR55K/MR-J3-CR55K4 MR-CR55K/MR-CR55K4
No.
Name and function
Initial
value
No.
Name and function
Initial
value
PA17 For manufacturer setting
Do not change this value by any means.
0000h
PA17 Function selection A-5
The [Pr. PA17 SEMI-F47 function selection] and [Pr.
PA18 SEMI-F47 function - Instantaneous power failure
detection time] settings of the converter unit must be
the same as [Pr. PA20 SEMI-F47 function selection]
and [Pr. PF25 SEMI-F47 function - Instantaneous
power failure detection time] settings of the drive unit.
_ _ _ x:
[AL. 10 Undervoltage] detection method selection
Set this parameter when [AL. 10] occurs due to
distorted power supply voltage waveform.
0: [AL. 10] not occurrence
1: [AL. 10] occurrence
1h
_ _ x _:
SEMI-F47 function selection
0: Disabled
1: Enabled
Selecting "1" enables to avoid triggering [AL. 10
Undervoltage] using the electrical energy charged in
the capacitor in case that an instantaneous power
failure occurs during operation. In [Pr. PA18 SEMI-F47
function - Instantaneous power failure detection time],
set the time until the occurrence of [AL. 10
Undervoltage].
0h
_ x _ _:
For manufacturer setting
0h
x _ _ _:
For manufacturer setting
0h
PA18 For manufacturer setting
Do not change this value by any means.
0000h
PA18 SEMI-F47 function - Instanta-neous power failure
detection time
The [Pr. PA17 SEMI-F47 function selection] and [Pr.
PA18 SEMI-F47 function - Instantaneous power failure
detection time] settings of the converter unit must be
the same as [Pr. PA20 SEMI-F47 function selection]
and [Pr. PF25 SEMI-F47 function - Instantaneous
power failure detection time] settings of the drive unit.
Set the time until the occurrence of [AL. 10
Undervoltage].
To disable the parameter setting value, select
"Disabled (_ _ 0 _)" of "SEMI-F47 function selection" in
[Pr. PA17].
Setting range: 30 to 200
200 [ms]
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...