Part 2: Review on Replacement of MR-J3-_A_ with MR-J4-_A_
2 - 28
MR-J3-_A_ MR-J4-_A_
Control
mode
No.
Name and function
Initial
value
No.
Name and function
Initial
value
PA15 Encoder output pulse
Turn off the power and then on again after setting
the parameter to validate the parameter value.
Used to set the encoder pulses (A-phase, B-phase)
output by the servo amplifier.
You can use parameter [Pr. PC19] to choose the
output pulse setting or output division ratio setting.
The number of A/B-phase pulses actually output is
1/4 times greater than the preset number of pulses.
The maximum output frequency is 4.6 Mpulses/s
(after multiplication by 4). Use this parameter within
this range.
(1) For output pulse designation
Set "_ _ 0 _" (initial value) in [Pr. PC19].
Set the number of pulses per servo motor
revolution.
Output pulse = set value [pulses/rev]
For instance, set "5600" to [Pr. PA15], the
actually output A/B-phase pulses are as
indicated below.
4
5600
A/B-phase output pulses
1400 [pulse]
(2) For output division ratio setting
Set "0 0 1 0" in parameter [Pr. PC19]
The number of pulses per servo motor revolution
is divided by the set value.
Output pulse
[pulses/rev]
Resolution per servo motor revolution
Set value
For instance, set "8" to [Pr. PA15], the actually
A/B-phase pulses output are as indicated below.
A/B-phase output pulses =
262144
8
= 8192 [pulses
・
1
4
(3) When outputting pulse train similar to command
pulses
Set [Pr. PC19] to "_ _ 2 _". The feedback pulses
from the servo motor encoder are processed and
output as shown below. The feedback pulses can
be output in the same pulse unit as the command
pulses.
CDV
FBP
Pt
"0"(Initial value)
CMX
Parameter No.PA06, PA07
Parameter No.PA05
Servo motor
Encoder
A/B-phase output pulses
Feedback pulse
M
Other than "0"
4000
PA15 Set the encoder output pulses from the servo
amplifier by using the number of output pulses per
revolution, dividing ratio, or electronic gear ratio.
(after multiplication by 4)
To set a numerator of the electronic gear, select "A-
phase/B-phase pulse electronic gear setting (_ _ 3
_)" of "Encoder output pulse setting selection" in [Pr.
PC19].
The maximum output frequency is 4.6 Mpps (after
multiplication by 4). Use this parameter within this
range.
Setting range: 1 to 4194304
4000 P
S
T
PA16
Set a denominator of the electronic gear for the A/B-
phase pulse output.
To set a denominator of the electronic gear, select
"A-phase/B-phase pulse electronic gear setting (_ _
3 _)" of "Encoder output pulse setting selection" in
[Pr. PC19].
Setting range: 1 to 4194304
1 P
S
T
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...