Part 3: Review on Replacement of MR-J3-_B_ with MR-J4-_B_
3 - 40
MR-J3-_B_
MR-J4-_B_
No.
Name and function
Initial
value
No.
Name and function
Initial
value
PD02 For manufacturer setting
Do not change this value by any means.
0000h
PD02 Input signal automatic on selection 2
_ _ _ x
(HEX)
_ _ _ x:
FLS (Upper stroke limit) selection
0: Disabled
1: Enabled
0h
_ _ x _ :
RLS (Lower stroke limit) selection
0: Disabled
1: Enabled
_ x _ _ :
For manufacturer setting
x _ _ _ :
For manufacturer setting
_ _ x _
(HEX)
For manufacturer setting
0h
_ x _ _
(HEX)
For manufacturer setting
0h
x _ _ _
(HEX)
For manufacturer setting
0h
Convert the setting value into hexadecimal as follows.
0
BIN 0: Use for an external input signal.
BIN 1: Automatic on
Initial value
BIN HEX
Signal name
0
0
0 0 0
0
0
FLS (Upper stroke limit) selection
RLS (Lower stroke limit) selection
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...