(7) Test operation mode (command [0] [0])
Command Data
No.
MR-J3-_A_/MR-J4-_A_
Description
Frame
length
[0] [0]
[1] [2]
Test operation mode reading
0000: Normal mode (not test operation mode)
0001: JOG operation
0002: Positioning operation
0003: Motor-less operation
0004: Output signal (DO) forced output
4
(8) Software version (command [0] [2])
Command Data
No.
MR-J3-_A_/MR-J4-_A_
Description
Frame
length
[0] [2]
[9] [0]
Servo motor-side pulse unit absolute position
8
[9] [1]
Command unit absolute position
8
[7] [0]
Software version
16