Part 8: Review on Replacement of Optional Peripheral Equipment
8 - 22
(2) DC 48 V/24 V class wires for power supply wiring
The following diagram shows the wires used for wiring. Use the wires or equivalent given in this section.
These sizes are common for the 600V Polyvinyl chloride insulated wire (IV wire) and for the 600V Grade
heat-resistant polyvinyl chloride insulated wire (HIV wire).
24VDC power
supply
48VDC power
supply
Encoder cable
Motor power
supply cable
Servo motor
Servo amplifier
B1
B2
1)
3)
2)
CN2A
CNP1
CNP2A
Encoder cable
Motor power
supply cable
Servo motor
B1
B2
3)
CN2B
CNP2B
PM
24
0
Wire size selection example (IV/HIV wire)
Servo amplifier
Wire (Note 1)
1) 24/0/PM/
2)
U/V/W/
3)
B1/B2
MR-J3W-0303BN6 AWG16 (Note 2, 3)
AWG19
1.25mm
2
(AWG16)
Note 1. This is a selection example when HG-AK0336(B) are used for two axes.
2. Insulator OD: 2.9 mm
3. Voltage drop will occur according to line impedance and current
supplied to the servo amplifier. Be sure to use this wire.
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...