Part 6: Common Reference Material
6 - 61
2.3 MR-J3-_B_ and MR-J3W-_B Parameter Diversion Procedure
The parameter converter functions of GX Works2 and MT Developer2 convert the servo parameters of MR-
J3-_B_ and MR-J3W-_B to those of MR-J4-_B_ MR-J4W2-_B and when the controller is changed.
(GX Works2: 1.84N or later, MT Developer2: 1.41T or later)
POINT
Parameters common to MR-J3-_B_, MR-J3W-_B, MR-J4-_B_ and MR-J4W2-_B
are the conversion targets.
The initial value of MR-J4-_B_ and MR-J4W2-_B is set for additional parameters
of MR-J4-_B_ and MR-J4W2-_B.
(Target model)
• Positioning module QD75MH to Simple Motion module QD77MS/LD77MS
• Motion controller Q17nHCPU/Q17nDCPU/Q170MCPU to Q17nDSCPU/Q170MSCPU(-S1)
GX Configurator-QP
SW3RNC-GSV
SW6RNC-GSV
GX Works2 (Simple Motion module setting tool)
MT Developer2
Change MR-J3-_B_/MR-J3W-_B to MR-J4-_B_/MR-J4W2-_B
Change controller
(parameter converter)
Project file
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...