Part 6: Common Reference Material
6 - 34
(2) SSCNET III/H cable specifications
POINT
SSCNET III cables can be used as they are.
Description
SSCNET III/H cable model
MR-J3BUS_M MR-J3BUS_M-A
MR-J3BUS_M-B
SSCNET III/H cable length
0.15 m
0.3 m to 3 m
5 m to 20 m
30 m to 50 m
Optical cable
(cord)
Minimum bend
radius
25 mm
Enforced covering cable:
50 mm
Cord: 25 mm
Enforced covering cable:
50 mm
Cord: 30 mm
Tension strength
70 N
140 N
420 N
(Enforced covering cable)
980 N
(Enforced covering cable)
Temperature
range for use
(Note)
-40 °C to 85 °C
-20 °C to 70 °C
Atmosphere
Indoors (not exposed to direct sunlight), no solvent or oil.
Appearance [mm]
2.2 0.07
4.4 0.1
2.2
0.0
7
4.4 0.1
6.0 0.2
2.
2
0.
07
4.4 0.4
7.6 0.5
2.
2
0.
2
Note. This temperature range for use is the value for optical cable (cord) only. Temperature condition for the connector is the same as
that for servo amplifier.
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...