Part 8: Review on Replacement of Optional Peripheral Equipment
8 - 62
Servo amplifier
Power factor
improving DC
reactor
Outline
drawing
Dimensions [mm]
Termin
al size
Mass
[kg]
Wire [mm
2
]
(Note 2)
W W1 H
D
(Note 1)
D1 D2 D3
d
MR-J4-10_,
MR-J4-20_
FR-HEL-0.4K
Fig. 8.3
70 60 71 61
21
M4 M4 0.4
2 (AWG 14)
MR-J4-40_ FR-HEL-0.75K
85
74
81 61
21
M4
M4 0.5
MR-J4-60_,
MR-J4-70_
FR-HEL-1.5K 85
74
81
70
30 M4
M4
0.8
MR-J4-100_ FR-HEL-2.2K
85
74
81 70
30
M4 M4 0.9
MR-J4-200_ FR-HEL-3.7K
Fig. 8.4
77 55 92 82 66 57 37 M4 M4 1.5
MR-J4-350_
FR-HEL-7.5K
86
60
113
98
81
72
43
M4
M5
2.5
3.5 (AWG 12)
MR-J4-500_ FR-HEL-11K
105 64 133 112 92 79 47 M6 M6 3.3 5.5
(AWG
10)
MR-J4-700_ FR-HEL-15K
105 64 133 115 97 84 48.5 M6 M6 4.1 8
(AWG
8)
MR-J4-11K_ FR-HEL-15K
105 64 133 115 97 84 48.5 M6 M6 4.1 14
(AWG
6)
MR-J4-15K_ FR-HEL-22K
105
64 93 175 117
104
115
(Note 1)
M6
M10
5.6
22 (AWG 4)
MR-J4-22K_ FR-HEL-30K Fig.
8.5
114
72
100 200 125
101
135
(Note 1)
M6
M10
7.8
38 (AWG 2)
Note 1. Maximum dimensions. The dimension varies depending on the input/output lines.
2. Selection conditions of wire size are as follows.
Wire type: 600 V grade heat-resistant polyvinyl chloride insulated wire (HIV wire)
Construction condition: Single wire set in midair
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...