Part 3: Review on Replacement of MR-J3-_B_ with MR-J4-_B_
3 - 22
MR-J3-_B_
MR-J4-_B_
No.
Name and function
Initial
value
No.
Name and function
Initial
value
PA19 Parameter write inhibit
[Pr. PA19]
setting
Setting
operation
Basic
setting
[Pr. PA _ _]
Gain/filter
[Pr. PB_ _]
Extension
setting
[Pr. PC_ _]
I/O setting
[Pr. PD_ _]
0000h
Reference
Write
000Bh
(initial
value)
Reference
Write
000Ch
Reference
Write
100Bh
Reference
Write
[Pr. PA19]
only
100Ch
Reference
Write
[Pr. PA19]
only
: Enabled
000Bh
PA19 Parameter writing inhibit
Select a reference range and writing range of the
parameter.
See the table below for the setting value.
[Pr. PA19] setting value and reading/writing range
PA19
Setting
operation
PA PB PC PD PE PF PL
Other than
below
Reading
Writing
000Ah
Reading
19
only
Writing
19
only
000Bh
Reading
Writing
000Ch
Reading
Writing
000Fh
Reading
Writing
00AAh
Reading
Writing
00ABh
(initial value)
Reading
Writing
100Bh
Reading
Writing
19
only
100Ch
Reading
Writing
19
only
100Fh
Reading
Writing
19
only
10AAh
Reading
Writing
19
only
10ABh
Reading
Writing
19
only
: Enabled
00ABh
PB01 Adaptive tuning mode (adaptive filter II)
Select the setting method for filter tuning. Setting this
parameter to " _ _ _ 1" (filter tuning mode 1)
automatically changes the machine resonance
suppression filter 1 [Pr. PB13] and notch shape selection
[Pr. PB14].
Machine resonance point
Notch frequency
Frequency
Frequency
Re
sp
on
se of
m
e
ch
an
ic
al sy
st
em
Notc
h d
ept
h
0 0 0 x:
Filter tuning mode selection
0: Filter OFF ([Pr. PB13/PB14] are fixed to the initial
values.)
1: Filter tuning mode (Automatically set parameter: [Pr.
PB13/PB14])
2: Manual mode
When this parameter is set to "_ _ _ 1", the tuning is
completed after positioning is done the predetermined
number or times for the predetermined period of time,
and the setting changes to " _ _ 2 _". When the filter
tuning is not necessary, the setting changes to "_ _ _ 0".
When this parameter is set to "_ _ _ 0", the initial values
are set to the machine resonance suppression filter 1
and notch shape selection. However, this does not occur
when the servo off.
0000h
PB01 Adaptive tuning mode (adaptive filter II)
Set the adaptive tuning.
_ _ _ x:
Filter tuning mode selection
Select the adjustment mode of the machine resonance
suppression filter 1.
0: Disabled
1: Automatic setting
2: Manual setting
0h
_ _ x _ :
For manufacturer setting
0h
_ x _ _ :
For manufacturer setting
0h
x _ _ _ :
uning accuracy selection
0: Standard
1: High accuracy
The frequency is estimated more accurately in the high
accuracy mode compared to the standard mode.
However, the tuning sound may be larger in the high
accuracy mode.
This digit is available with servo amplifier with software
version C5 or later.
0h
Summary of Contents for Melservo MR-J3-100B
Page 17: ...8 MEMO ...
Page 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Page 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Page 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Page 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Page 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Page 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Page 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Page 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Page 589: ...L NA 03127ENG C ...