1938
30 SELECTION FUNCTIONS
30.4 Multiplexer
30.4
Multiplexer
MUX(_E)
These functions output one of the input values.
*1 The input variable s can be changed within the range from 2 to 28.
Setting data
■
Description, type, data type
Processing details
■
Operation processing
• These functions output one of the values input to (s1) to (s28), in the same data type as (s), from (d) according to the value
input to (n).
• If the (n) input value is 0, the value input to (s1) is output from (d).
• If the (n) input value is (n)-1, the value input to (sn) is output from (d).
Ex.
Data type: INT
• If a value outside the range of the number of pins in (s) is input to (n), an undefined value is output from (d). (No operation
error occurs. When MUX_E is used, ENO outputs FALSE.)
• Input an INT data type value to (n) within the range of 0 to 27, provided that it is within the range of the number of pins in (s).
• Input a BOOL, INT, DINT, WORD, DWORD, REAL, LREAL, STRING, TIME, structure, or array data type value to (s).
Ladder, FBD/LD
Structured text
[Without EN/ENO]
[With EN/ENO]
[Without EN/ENO]
d:=MUX(n,s1,s2);
[With EN/ENO]
d:=MUX_E(EN,ENO,n,s1,s2);
Argument
Description
Type
Data type
EN
Execution condition (TRUE: Executed, FALSE: Not executed)
Input variable
BOOL
n(K)
Output value selection
Input variable
INT
s1 (IN0) to s28 (IN27)
Input
Input variable
ANY
ENO
Output status (TRUE: Normal, FALSE: Abnormal)
Output variable
BOOL
d
Output
Output variable
ANY
RnCPU RnENCPU
RnSFCPU RnSFCPU
RnPCPU
RnPCPU
(Standard)
(Safety)
(Redundant)
(Process)
n
d
s1
s2
EN
ENO
d
n
s1
s2
(s1)
(s28)
(d)
n
1234
5678
1234
0
MUX
_K
_IN0
_IN1
MUX
INT
INT
INT
INT
…
Summary of Contents for MELSEC iQ-R Series
Page 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Page 34: ...32 MEMO ...
Page 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Page 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Page 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Page 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Page 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...
Page 2109: ......